Flowzone CONCRETE+ MONSOON 2.5 Скачать руководство пользователя страница 2

C MONSOON 2.5 

OPERATION GUIDE

FZVACF-2.5

© WESSOL, LLC 2022

!

ATTENTION

Please read the following information carefully.  User must read and understand the entire manual before 

operating the sprayer. Failure to follow instructions or improper use could lead to sprayer failure and 

possible serious injuries.

This product contains chemicals, including lead, known to the state of California 
to cause birth defects and other reproductive harm.

When using chemicals, always wear protective clothing, including respiratory 
protection masks, gloves, eye protection, etc.

Do not dispose of Lithium-ion batteries with household waste; recycle where 
facilities exist.

• 

Never  spray  flammable,  caustic, 
acidic,  heat,  pressure,  or  gas 
producing chemicals. 

• 

Always  read  and  follow  chemical 
manufacturer’s 

instructions 

before  use  with  this  sprayer  as 
some chemicals may be hazardous 
when used with this sprayer.

• 

Never leave chemicals or solutions 
sitting in your sprayer after using.

• 

After 

using 

sprayer 

with 

chemicals, it is important to spray 
with fresh water for 3-5 minutes to 
ensure  residual  chemicals  in  the 
gun,  wand,  tank,  pump,  and  hose 
are cleaned out. 

• 

Read  and  follow  all  instructions 
and cautions on label of products 
used in this sprayer.

• 

Do  not  store  your  sprayer  in 
extremely  high  temperatures. 
Heat  can  lead  to  the  build-up 

of  pressure  within  the  sprayer, 
resulting in a possible explosion. 

• 

Do not try to make modifications to 
the sprayer.  Always use FlowZone

®

 

branded  replacement  parts  from 
the manufacturer. 

• 

Do  not  use  batteries  that  are  wet 
or have been damaged. 

• 

Inspect sprayer hose, power knob, 
wand, and gun for damage or loose 
connections before each use.

• 

Do not lift or carry the sprayer by 
the  hose,  or  wand.  Carry  by  the 
handle only. 

• 

Only spray when the air is calm (no 
wind  or  air  movement)  to  prevent 
chemical  spray  from  drifting  into 
unintended areas.

• 

Keep sprayer and all chemicals out 
of the reach of children.

• 

Remove chemicals and thoroughly 
clean  the  sprayer  after  each 

use.  Failure  to  clean  the  sprayer 
may  cause  contamination  of 
subsequent  applications,  will 
cause  premature  spray  ware, 
and  void  the  sprayer  warranty. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTES

• 

The  sprayer  may  have  residual 
water  in  it  when  first  opened. 
This is due to quality testing every 
sprayer  undergoes  before  leaving 
our factory. 

• 

Some parts may be located under 
the tank lid when first assembling 
the sprayer. 

• 

THIS SPRAYER IS DESIGNED TO 

OPERATE WITH ONLY FLOWZONE

®

 

BRANDED BATTERIES. ANY 

OTHER BATTERIES COULD CAUSE 

SERIOUS HARM OR INJURY  TO 

THE OPERATOR AND SERIOUS 

DAMAGE TO THE SPRAYER. 

2

Содержание CONCRETE+ MONSOON 2.5

Страница 1: ...CONCRETE MONSOON 2 5 OPERATION GUIDE FZVACF 2 5 WESSOL LLC 2022 5 POSITION VARIABLE PRESSURE BATTERY POWERED ROLLING SPRAYER 9 GALLON TANK CAPACITY OPERATION GUIDE Model FZVACF 2 5 1 ...

Страница 2: ...uctions and cautions on label of products used in this sprayer Do not store your sprayer in extremely high temperatures Heat can lead to the build up of pressure within the sprayer resulting in a possible explosion Do not try to make modifications to the sprayer Always use FlowZone branded replacement parts from the manufacturer Do not use batteries that are wet or have been damaged Inspect spraye...

Страница 3: ...ayer out of reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the sprayer Power tools are dangerous in the hands of untrained users Maintain sprayers and accessories Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the sprayers operation SAFETY Use the sprayer and accessories in acco...

Страница 4: ...er before each use Check for cracked and deteriorated hoses leaks clogged nozzles and missing or damaged parts If damaged ensure the sprayer is repaired before use Many accidents are caused by poor maintenance Always remove the battery pack from the sprayer before performing any maintenance storing or draining of the sprayer Do not eat or smoke while handling or operating the sprayer Refer to the ...

Страница 5: ... 1 1 specifications page 6 1 2 what s in the box page 7 ABOUT page 6 7 2 1 assembly page 8 2 2 spraying page 10 2 3 aftercare page 12 SET UP page 8 12 3 1 parts and accessories page 13 3 2 troubleshooting page 15 page 13 15 MAINTENANCE 4 1 warranty policy page 16 page 16 WARRANTY 5 ...

Страница 6: ...4 gal min Battery Charger 21V 2 5A Pump Life 1 000 hours Harness the convenience of the GHT quick connect hose by switching between spraying chemicals and delivering water to tools such as cut saws and core drills Easily comply with OSHA Table 1 regulations with FlowZone Concrete Easily switch from delivering water through tools to spraying chemicals such as curing compounds form release cleaning ...

Страница 7: ...allon Tank 8 20 Ft GHT GHT Hose 14 25 Fan Nozzle 3 Tank Strainer 9 Spray Gun 15 Wheels Cotter Pins 4 Top Bottom Holster 10 18V 5 2Ah Battery Pack 16 Handle with Storage 5 Nuts Bolts 11 21V 2 5A Charger 6 Hose Storage Brackets 12 Adjustable Cone Nozzle WHAT S INSIDE For part numbers and replacement parts please see page 14 1 11 2 3 6 5 8 4 9 10 7 12 13 14 15 16 7 ...

Страница 8: ...pin open to secure the wheel on to the axel Repeat for the other wheel 3 Next place the top wand holster at the protruding holster mount on the sprayer tank While holding the holster in place insert a nut on one side of the hexagonal slot andscrewtheboltthrough the other side using a Philip s head screwdriver until the bolt fastens into the nut Repeat for the bottom holster slot 4 Stand the spraye...

Страница 9: ...bracket 7 Connect the male end of the hose 8 with the female end of the jumper hose attached to the sprayer tank Pull back the collar on the female GHT fitting insert the hose and release the fitting 8 Attach the spray gun 8 to the female end of the hose using the same method 9 If spraying with the stainless steel spray wand 7 pull back on the collar of the quick connect fitting on the spray gun a...

Страница 10: ...tery is plugged in and charging 2 In a separate container prepare the solution you want to spray according to the chemical manufacturer s instructions Remove the tank lid and carefully pour the solution through the tank strainer Securely tighten the tank lid 3 Determine the nozzle you would like to use and insert it into the spray gun or spray wand 4 Turn the pump on by rotating the variable press...

Страница 11: ...S Store the battery pack where the temperature is below 80ºF and away from moisture Store the battery pack in a 30 50 charged condition For long term storage regular charging of the battery is required to maximize battery life Check the battery level using the indicator lights every 4 weeks Recharge the battery if it falls below 3 bars Do not allow the battery to fully discharge BATTERY RECYCLING ...

Страница 12: ...the hose and allow the hose to hang down towards the ground draining the hose of excess liquid 4 Thoroughly dry the sprayer tank with a clean cloth and clear the nozzles and internal inlet filter of any buildup 5 Store the sprayer in a dry clean and shaded place to protect it from extreme heat or frost Never leave your sprayer exposed in the back of a vehicle NOTE For long term storage regular cha...

Страница 13: ...N Quick Connect Spray Gun FZRADJ Rolling Sprayer Wheels FZAAEM 18V 5 2Ah Battery Pack FZRAES High Variable Pressure Pump Circuit Board Assembly FZRADE Sprayer Handle with Storage FZAAEL 21V 2 5A Charger FZRAFF Diaphragm Pump FZRAHP Drain Plug FZRAFJ Circuit Board ACCESSORIES REPLACEMENT PARTS All parts and accessories can be purchased online at www fzspray com FZRACU FZRAHP FZRABW FZRAGM FZRACS FZ...

Страница 14: ...E MONSOON 2 5 OPERATION GUIDE FZVACF 2 5 WESSOL LLC 2022 Part Name Part Name Part Name FZAAAR Adjustable Cone Nozzle FZAAAP Quick Connect 0 Jet Nozzle FZAAAQ Quick Connect 25 Fan Nozzle FZAAAQ FZAAAR FZAAAP 14 ...

Страница 15: ...d nozzle Not rinsing tank pump hose gun nozzle s with water after use Rinse sprayer throughly with warm soapy water after each use Dead battery Defective charger If the LED indicator lights do not turn on or only one red LED is on after being on charger for over 2 hours test the charger using a multimeter Replace if necessary Damaged lithium cells If the battery receives no reading from a multimet...

Страница 16: ...CLUSIONS AND LIMITATIONS WESSOL LLC only warrants products purchased from authorized distributors Products purchased from unauthorized resellers or distributors are not subject to warranty services The limited warranty does not cover damages loss or injury resulting from transportation storage accident improper use neglect modifications normal wear or operation not in accordance with the instructi...

Страница 17: ...CONCRETE MONSOON 2 5 OPERATION GUIDE FZVACF 2 5 WESSOL LLC 2022 17 fzspray com concreteplus spraysquad fzspray com 1 803 339 2500 WESSOL LLC 2022 ...

Отзывы: