7.2.2
Suction Pipe [Inlet Of Vacuum Pump]
Avoid Flooding: The suction pipe must be laid with a gradient to the vacuum system so that pockets
are not formed and liquid (e.g. condensate) does not flood into the pump The SIHIdry
system can
handle a low continuous liquid flow only if it is assured that the liquid does not react with materials. The
condensate cannot be fed if other vacuum pumps are integrated into this system (e.g. lobular pump).
Avoid Liquid / Particle Carry Over: Install a liquid or condensate separator in the suction pipe for
large liquid or condensate volumes and lay the outlet with a large cross-section and a downward
gradient so that counter pressure does not develop in the pump outlet due to accumulation of liquid.