5
4
5.4 PS/PM UltraSwitch™ nomenclature
4. CERTIFICATES
ATEX II 1G Ex ia IIC T4/T5/T6
IEC Ex ia IIC T4/T5/T6
ATEX II 2 G Ex e mb IIC T6
cFMus IS Class I,II,III Division 1 Group A,B,C,D,E,F,G
cFMus NI Class I Division 2 Group A,B,C,D; Class II Division 2 Group E,F,G; Class III Division 1&2
cCSAus Class I, Division 1 Groups A,B,C,D; Class II Division 1 Groups E,F,G; Classs III
cCSAus Class I, Division 2, Groups A,B,C,D; Class II, Division 2, Groups E,F,G; Class III
All certificates available for
download at www.pmv.nu
5. SPECIFICATIONS
5.1 Technical data
Ingress protection
IP66 & Type 4x
Weight
1 kg / 2.2 lbs
5.2 Materials of construction
Part
Material
Housing/Cover
PA6/PA66 Nylon 25% - 33% Glass Filled Engineered Resin
Shaft
Stainless
Steel
Cams/Splines Nylon
Terminal Block
Nylon – Buchanan TBS Series
Internal Brackets
Stainless Steel or Plated Steel
All Internal Fasteners
Stainless Steel or Plated Steel
All External Fasteners
Stainless Steel
All Molded in Fasteners
Anodized Aluminum
UltraDome™ Polycarbonate
Rotor
Polycarbonate
5.3 Type sign
Product name and model code
Warnings
Year of manufacture
S/N: XXXXXX
Manufacturer
Electrical rating
Serial number
Logotype
WARNING
POTENTIAL ELECTROSTATIC CHARGING HAZARD
SEE INSTRUCTIONS
POWER SOURCE MUST BE PROTECTED BY A FUSE
OF 3 A WITH BREAKING CAPACITY ≥ 1500A
Model code
Type sign for
Atex Ex e mb
PALMSTIERNA INTERNATIONAL AB, SOLNA, SWEDEN
S/N:
IP 66/Type 4X
DATE:
0470
Cl. I Div.2 Gr. A-D T6
Cl. I Div.2 Gr.A-D T4-6
Cl. II Div.2 Gr. E-G
Cl. I Div.1 Gr.A-D T5
Cl. II Div.1 Gr. E-G
Cl. III
NON INCENDIVE
Cl. II Div.2 Gr. E-G T6
II 1 G
11ATEX1065X
NEMKO
Ex ia IIC T4-T6 Gb
REFERENCE TO CONTROL DWG NO. RA-2 FOR SAFE USE
SAFTY AND SUITABILITY FOR DIVITION 2.
Div. 1,Gr A-G,T4-T6
CLASS I,II&III
INTRINSIC SAFY
SUBSTITUTION OF COMPONENTS MAY IMPAIR INSTRINSIC
Cl.III Div.1&2
WARNING:
POTENTIONAL ELECTROSTATIC CHARGING HAZARD- SEE
INSTRUCTIONS.
INTRINSIC SAFY
NON INCENDIVE
IECEx
NEM 11.0012X
*If the equipment is likely to come in contact with aggressive substances, it is the
responsibility of the user to take suitable precautions to prevent it from being
adversely affected, thus ensuring that the type of protection provided by the
equipment is not compromised.
A. Brand sticker
P
PMV
B. Shaft
N
NAMUR VDI/VDE 3845
D
Double D 1/4”
C. Connections (cable entry)
PS
Engineered Resin Housing 1/2 NPT
PM
Engineered Resin Housing M20x1,5
PN
Engineered Resin Housing 3/4 NPT
PG
Engineered Resin Housing M25x1,5
D. Number of cable entries
1
1 conduit
2
2 conduits
3
3 conduits
E. Indicator option
1
Flat cover without indicator
U
Standard UltraDome
TM
red/green
C
90 deg 3-way UltraDome
TM
D
180 deg 3-way UltraDome
TM
E
180 deg 3-way Centre-blocked UltraDome
TM
F
120 deg Thru/Divert UltraDome
TM
H
Black/Yellow UltraDome
TM
K
Ektar UltraDome
TM
(red/green)
R
Reverse UltraDome
TM
(red=open / green=closed)
X
180 deg 3-way UltraDome
TM
(white/blue)
F. Switch quantity
0
No Switches
2
2 Switches
4
4 Switches
G. Switch options
options
See page with switch options
H. Certificate
14
General Purpose
15
ATEX II 1G Ex ia IIC T4/T5/T6
21
IEC Ex ia IIC T4/T5/T6
22
ATEX II 2 G Ex e mb IIC T5/T6
27
FM IS Cl. l Div. 1 Grp. A, B, C, D; T4
28
FM NI, CSA NI Cl. l Div. 2 Grp. A, B, C, D, D
40
ATEX Ex ia, FM IS, CSA IS, IEC Ex ia
60
ATEX Ex ia, FM IS, CSA IS, IEC Ex ia, FM NI, CSA NI
I. Analog output
0
None
T
4-20 mA transmitter
D
180 deg 4-20 mA transmitter
A
0-1K Ohm Potentiometer
J. Wiring options
0
None
3
Brad Harrison Connectors - 7 pins
4
Weidmüller special AKZ 2,5
H
Heavy Duty Terminal Block
K. Minimum extra terminals
2
2 Open Terminal Locations (Standard)
4
4 Open Terminal Locations (2 SPST switches)
6
6 Open Terminal Locations (2 SPDT switches)
8
8 Open Terminal Locations (2 or 4 SPST switches)
L. Special options
0
None
V
Viton O-rings
FCD PMENIM0008-02 - 08/14
FCD PMENIM0008-02 - 08/14