Operating Procedures: 

Depending on pump model and mounting arrangement the pump can be mounted in either a vertical 

or horizontal (optional accessories required) position. 

-Vertical Mounting (PH6 Pump, PH6P, and varieties): 

1. Secure pump to tank using appropriate customer supplied fitting. 

2. Secure 1-inch hose to the 1-inch discharge port of pump. 

3. Connect Terminal Clamps to the positive (red) and negative (black) terminals on a 12-15 volt, 

DC power source. 

-Vertical Mounting (PH6P-MM, PH6P09, PH6P16): 

1. Secure pump to tank by fitting the 3 pin male Micro Matic coupler into the appropriate 3 slot 

female Micro Matic coupler and dip tube assembly, and lock into place. 

2. Secure 1-inch hose to the 1-inch discharge port of pump. 

3. Connect Terminal Clamps to the positive (red) and negative (black) terminals on a 12-15 volt, 

DC power source. 

-Horizontal Mounting (CES-PH6 and most standard varieties): 

*Note: Some configurations will have differing fittings used to connect pump to tank. The general procedure for 

installation is, to connect the pump to the tank first, and then secure the motor bracket to the tank, tightening all 

connections afterward. 

1. In the horizontal position screw the 2-inch Street Elbow onto the bottom 2-inch male NPT 

suction port of the pump. 

2. Secure 2-inch to 1-inch Bung Adapter fitting to the free end of 2-inch Elbow. 

3. Secure to tank per connection instructions. 

4. Adjust Motor Support Bracket to properly support the Motor in a level, horizontal position. 

5. Secure 1-inch hose to the 1-inch discharge port of the pump (or if using a pump mounted 

SEM-10 meter, the discharge port of the meter). A 1-inch elbow may be used to position hose 

in direction of service. 

6. Connect Terminal Clamps to the positive (red) and negative (black) terminals on a 12-15 volt, 

DC power source. 

For CES-MTS pump installation, see the specialized IOM manual included with your pump. 

Recommended Practices: 

- These pumps were designed to be used with an 8-12 foot long hose. Use with longer hoses 

will decrease flow rate. 

DO NOT 

leave power switch in the “on” position when pump is not in use. This could lead to 

complete emptying of tank if a leak occurs.

 