Страница 1: ...are Viton PHP KIT 03 This power switch kit contains a replacement On Off Toggle Switch Molded Junction Box Cover and screws PH6 KIT 01 This kit contains a re placement Nylon Pump Housing and 6 screws PH6M01 This motor kit contains a replacement Motor Assembly consisting of the 12 volt motor assembly with Ca bles Terminal Connection Clamps and Wobble Plate PHA 06 This kit contains a replacement red...
Страница 2: ......
Страница 3: ...k The general procedure for installation is to connect the pump to the tank first and then secure the motor bracket to the tank tightening all connections afterward 1 In the horizontal position screw the 2 inch Street Elbow onto the bottom 2 inch male NPT suction port of the pump 2 Secure 2 inch to 1 inch Bung Adapter fitting to the free end of 2 inch Elbow 3 Secure to tank per connection instruct...
Страница 4: ...m 12 15 volt DC power source 3 Remove Motor by removing the six 6 Screws from the pump assembly 4 Remove Cartridge from Pump Housing by placing blunt object Screw Driver Handle etc into the suction port of Pump Housing and push the Cartridge out of Pump Housing Do Not pry cartridge from the Pump Housing as damage to O ring area can occur Cartridge Installation 1 Assure bottom Pump Housing Gasket i...