12. Secure the hose end in the correct place on the frame.
13. Ensure the hydraulic valve is taken out of the freewheel position.
14. Replace the antifreeze tank lid.
15. Isolate the machine
If the pump is frozen up
– it should on no account be started. Operating the machine frozen will damage
the pump and damages caused by misuse will not be covered under warranty.
NOTE: The hose should NEVER be tightly wound onto the hose reel drum when the hose is not pressurised, as
might occur when the hose has become trapped. A tightly wound hose can easily crush the hose reel when it is
next pressurised. If you have reason to believe that the hose may have been tightly wound onto the reel when
unpressurised it should be completely unwound and then rewound loosely before pressurising.