4) Clean the surface of installation points
Paint, rust and anticorrosive coating on installation points need to be cleaned. It’s good to use a
polishing machine to get the metal luster.
As shown below:
5) Install transducers
After transducer wiring and sealing, please evenly smear 2
-
3mm couplant on the transducer
emitting surface. Then put the transducers on the installation points, fixed with steel belt or steel
rope.
6) Check Installation
Please see details in Chapter 7.5
7.3
Insertion type transducer installation
! Before installation, please verify the parameters of pipeline and liquid. To ensure
the installation accuracy.
1)
Installation procedure
Select an installation method → Input the measuring parameters → Positioning installation
points
→ Fix ball valve base →
Open hole under pressure
→ Install transducers → Check the
installation
2)
Select installation method and positioning installation points
Insertion type transducers are suitable for pipe sizes > 50mm.
Two different installation methods: V method and Z method. Generally use Z method, only
use V method for lack of space.
>> V method
V method can be used for DN50mm
-
300mm. Let the pair of transducers horizontal
alignment, the central line in parallel with the pipeline axis, and the transmit direction mush
be opposite.
Page 16