QS204260 Rev B
3
|
MOUNTING PODVIEW
®
PodView
®
is designed for panel mount installations, either located within an instrument panel or through the
wall of a NEMA box enclosure.
Panel Installation
The maximum cable distance between PodView
®
and EchoPod
®
is 15’ (4.5m). Follow the below steps to
install the indicator in a panel or NEMA box enclosure located near EchoPod
®
.
1.
Drill (1) large 0.75” (19.1mm) diameter hole in the panel for the cable and threaded nipple.
2.
Drill (1) small 0.25” (6.4mm) diameter hole 0.83” (21.1mm) below the large hole that will prevent the
installed indicator from rotating off center.
3.
From the front side of the panel, insert the indicator cable through the large diameter top hole.
4.
Properly align the indicator with the flat gasket and holes on the panel, and press the indicator in place
against the panel.
5.
From the rear side of the panel, insert the cable through the locking nut and tighten the locking nut
down over the threaded nipple.
6.
Route the indicator cable for wiring termination.