FlowLine LP10 Series Скачать руководство пользователя страница 2

Step One

SPECIFICATIONS

Dimensions

Accuracy:

±

1 mm in water

Repeatability:

±

 .5 mm in water

Dielectric range:

> 20 constants

Conductive range:

> 100 micromhos

Supply voltage:

12 - 36 VDC

Consumption:

Relay: 25 mA
FET:

5mA,  

±

 1mA (dry)

19 mA, 

±

 1mA (wet)

Relay rating:

60 VDC/VAC @ 1A

FET rating:

36 VDC max. @ 100 mA max.

Switch output:

Selectable NO or NC

Temperature range:

F: -40

°

 to 194

°

C: -40

°

 to 90

°

Pressure range:

150 psi (10 bar) @ 25 

°

C., derated @ 1.667

psi (0.113 bar) per 

°

C. above 25 

°

C.

Sensor material:

Polypropylene (PP) or Perfluoroalkoxy (PFA)

Sensor rating:

NEMA 6 (IP68)

Mounting threads:

Short: 3/4" NPT (3/4" BSP)
Long: 3/4" NPT (3/4" G)

Mounting gasket:

Viton (3/4"), metric only

Cable type:

8 ft. (2.5 m), 4-wire (relay) or 3-wire (FET),
22 gauge with shield & PP or PFA jacket

CSA approval:

Class I, Groups A, B, C & D;
Class II, Groups E, F & F; Class III

CSA entity parameters: V

max

 = 32 VDC

I

max

 = 0.5 A

C

i

 = 0 

µ

F

L

i

 = 0 mH

Certificate number:

LR 79326-4

CE compliance:

EN 50082-2 immunity
EN 55011 emission

*All dimensions

are nominal

Red Wire

Black Wire

Shield

HAZARDOUS LOCATION

     

Class I, Groups A,B, C, and D

     Class II, Groups E, F, and G

     Class III, (see note 1)

NON-HAZARDOUS LOCATION

LP50 series sensor suitable for Class I, Groups A, B, C, and 
D locations only.
CSA certified associated equipment with entity parameters.
V

max

 

 V

oc

, I

max

 

 I

sc

, C

i

 + C

cable

 

 C

a

, L

i

 + L

cable

 

 L

a

.

Installation should be in accordance with CEC Part I, or 
NFPA 70.
Associated equipment must be installed per manufacturers 
instructions

Sensor Drawing: LSD1
Rev. A  7-21-95

Sensor Models

LP10
LP50

LU10
LO10

Entity Parameters

V

max

 = 32V

I

max

 = 0.5A

C

i

 

 0

L

i

 

 0

Associated

Equipement

(see notes 2 and 5)

Notes:
1.

2.
3.
4.

5.

(+)

(-)

FET
shld

8' Cable 

( 2 . 5   m )

0.7"

(19 mm)

2.1" 

(54 mm)

2.8" 

(70 mm)

4.5" 

(114 mm)

Red

Black

White

8' Cable 

( 2 . 5   m )

0.7"

(19 mm)

0.7"

(19 mm)

1.3" 

(32 mm)

3.0" 

(76 mm)

(+)

(-)

NO/NC

COM

shld

Red

Black

White

Green

               LP10 - _ _ _ _

Sensor Material

1 - PP
2 - PFA

Sensor Length

3 - Short
4 - Long

Mounting Thread

0 - 3/4" NPT
2 - 3/4" G

Switch Output

0 - Intrinsically Safe
2 - FET, N-Channel
3 - FET, P-Channel
5 - Relay

Capacitance Switch

1,600

1,400

1,200

1,000

800

600

400

200

0

12                      24                      36

Acceptable 

Range

Unacceptable 

Range

4-20 mA Sensor

Electrical Loading Limits

Max. Series Resistance (Ohms)

Supply Voltage (VDC)

160 

140

120

100

80

60

40

20

00

-40    -20    00    20    40    60    80   100

Acceptable 

Range

Unacceptable 

Range

Temperature / Pressure Derating

Operating Pressure (psi)

Temperature (

°

C)

PP

PFA

100

80

60

40

20

00

-20

-40

12      16      20      24      28      32      36

Acceptable 

Range

Unacceptable 

Range

Maximum Temperature / Voltage Derating

Continuous 20 mA Sinking Curve

Ambient Sensor 

T

emperature (

°

C)

Operating Voltage (VDC)

FET

Wiring

Relay

Wiring

Intrinsically Safe Control Drawing

Отзывы: