![FlowLine LC30-1001 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/flowline/lc30-1001/lc30-1001_owners-manual_2308142002.webp)
Step One
SPECIFICATIONS
Supply voltage:
120 / 240 VAC, 50 - 60 Hz.
Consumption:
5 watts
Strobe type:
10_1: N/A
10_2: Xenon tube
Strobe flash:
10_1: N/A
10_2: 1 per second
Sensor input:
(1) four-wire flow switch
Sensor supply:
13.5 VDC @ 100 mA
Contact type:
(1) SPDT
Contact rating:
250 VAC, 10A, 1/4 Hp
Contact delay:
0 to 60 seconds
LED indication:
Sensor, relay & power status
Electronics temp.:
F: -40° to 158°
C: -40° to 70°
Enclosure rating:
NEMA 4X (IP65)
Enclosure material:
10_1: PP (U.L. 94 VO)
10_2: PP (U.L. 94 VO) & polycarbonate
Encl. mount:
100_: 3/4” NPT
105_: 3/4” R
Enclosure rotation:
300° swivel base
Conduit entrance:
Single, 1/2" NPT
Classification:
general purpose
Certificate:
LR 79326-3
CE compliance:
EN 61326
EMC
EN 61010-1
Safety
Part Number Information:
Part #
Thread
Description
LC30-1001
(1) (2)
3/4” NPT
Flow or No-Flow Relay Controller
LC30-1051
(1) (2)
3/4” BSP
Flow or No-Flow Controller
LC30-1002
(2)
3/4” NPT
Flow or No-Flow Controller with Strobe Alert
LC30-1052
(2)
3/4” BSP
Flow or No-Flow Controller with Strobe Alert
(1)
Adding -CE to end of part number signify CE configuration of controller
(2)
Adding -E to end of part number signify 240 VAC configuration of controller
1.0"
(25mm)
4.7"
(1
19mm)
2.8"
(71mm)
3.2"
(81mm)
1.0"
(25mm)
2.8"
(71mm)
3.2"
(81mm)
6.4"
(162mm)
INVERINVER
T
+/- +/-
DELAY
AC
AC
GND
NC
C
NO
R
R
P
P
Input 1A
(S)
(-)
115 VAC
220 VAC
(+)
Latch/Invert Logic
Time Delay
Sensor
Input
1
+ - S
NO
NC
COM
AC
AC
GND
RELAY
POWER
SUPPLY
Dimension:
LC30-10_1
Dimension:
LC30-10_2
Internal Controller Logic
LC11-1001 Faceplate