MOUNTING ECHOTOUCH

®

 

 
The transmitter should always be mounted perpendicular to the liquid surface. Insure that there are no 
restrictions or obstacles in the path of the acoustic signal.  For further mounting information, please refer to the 
EchoTouch

®

 manual at www.flowline.com.   

Installation in existing 3” fittings:

 

Use a LM52-2400 3” thread x 2” thread adapter or a LM52-2410 3” 
slip x 3” thread adapter.  

Basic Tank Installation

Use a 2” bulkhead fitting, such as the LM52-2890 bulkhead fitting.     

Use a larger bulkhead fitting, such as the 3” LM52-3890 with a 
reducer bushing such as the LM52-2400 (3” to 2”). 

Use a flange with a 2” thread, such as the LM52-2850. 

Weld a plastic 2” half coupling to the tank top. 

Mounting in Riser:

 

Installations with tall, narrow risers can impede the acoustic signal. 
2" diameter risers should be no taller than 4". Larger diameter 
risers should be no taller than 12".  For best results, follow a 2:1 
Height to Inner Diameter ratio (example: 8” Height to 4” Inner 
Diameter or 12” Height to 6” Inner Diameter). 
 

Installation in open tanks and sumps: 

Use Flowline's LM50-1001 side mount bracket. 

 

Note:  The Side Mount Bracket (LM50 series) is not designed 
for use with stand pipes or as a method to secure stand pipes.  
There are too few threads to properly hold the transmitter and 
the stand pipe.  

 

          

 

LM50-1001 

 

LM52-2400 

 

LM52-2890 

 

 

LM52-2850 

 

 

Mounting in Riser 

 

 

 

 

Содержание EchoPod UG06-12

Страница 1: ...Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com QS300820 Rev A2 2018 Flowline Inc All Rights Reserved Made in USA US01 US03 US06 Series Quick Start EchoTouch Intrinsically Safe Reflecti...

Страница 2: ...6 0003 01 US06 0013 00 US06 0013 01 USB Key Fob P N LI99 2001 Viton gasket 2 P N 200129 G threaded version only WebCal Configuration Only WebCal Configuration Only Push Button or WebCal Configuration...

Страница 3: ...om o H WEBCAL hrough Web ting since it SOFTWARE re from www 8 10 10 MB ternet conne eeding to Ste B FOB Fob to your e sensor to t the software ect the displ tes to WebC xternal powe ch is 15 d unplug...

Страница 4: ...an It is based o n for the sen s based on t e below ndition for the t of liquid in sor Height an nits shown u nd Fill Heigh on the distan nsor bottom the distance e transmitte Loop Fail o Sets t the t...

Страница 5: ...ration and saves the configuration file to your hard drive Before configuration can be completed You must click the Write to Unit button to save the settings to the unit Then click Wiring Diagram for...

Страница 6: ...RE THE TANK Measuring the tank is one of the most important aspects in configuring the transmitter When measuring the tank take into account the location of the transmitter with respect to fittings ri...

Страница 7: ...EXIT by pressing OK to return to the TOP LEVEL MENU 9 Select RUN by pressing OK to return to Operational Mode Note The Height 4mA and Fill Height 20mA settings also determine the 4 to 20 mA current s...

Страница 8: ...such as the LM52 2400 3 to 2 Use a flange with a 2 thread such as the LM52 2850 Weld a plastic 2 half coupling to the tank top Mounting in Riser Installations with tall narrow risers can impede the a...

Страница 9: ...e minimum diameter of the pipe is 2 for the US01 and US03 series and 3 for the US06 series Larger diameter pipes can be used The pipe should be attached with a coupling or tank adapter and reducer bus...

Страница 10: ...upply to the input and to sense the current flow out of the output For all Intrinsically Safe applications refer to control drawing 600820 for the US06 series and 610125 for the US01 and US03 series A...

Страница 11: ...tible with the application Design a fail safe system for possible transmitter and or power failure When used as an intrinsically safe device always refer to control drawing 600820 for the US06 series...

Страница 12: ...2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowl...

Отзывы: