16
MN310125 Rev A2
Configuration
(continued)
Step Three
USB
®
FOB INTERFACE
EchoPod
®
communicates with WebCal
®
* through a USB
®
interface called a Fob (LI99-2001). Before plugging
your Fob into your computer’s USB
®
port, be sure that you have installed WebCal
®
(see
www.flowline.com/webcal-software/
) on your computer.
Connect the red, green, white and black wires from EchoPod
®
into the correct terminals on the Fob. Tighten
the screws on the terminals. Plug your Fob into the USB
®
port of your computer.
Wiring to Fob (LI99-2001)
LI99-2001 USB
®
Fob
Wiring is identical for all EchoPod
®
Series – Use only the Red, Black, Green and White wires.
The maximum cable distance between the computer and EchoPod
®
is 15’. This only applies for configuring
the EchoPod
®
.
Once EchoPod
®
is configured and prior to installation, isolate the white and green wires from active power
to prevent a short from the configuration circuit.
Note:
When using the Fob, do not add VDC or VAC power. The Fob, when connected to the computer, will
provide the required power to the EchoPod
®
.
* For complete information on the WebCal
®
software, please refer to the WebCal
®
manual located at
www.flowline.com/webcal-software/.
Note:
Only use the
LI99-2001
USB
®
Fob (white). The
LI99-1001
USB
®
Fob
(black)
will not work
with the
EchoPod
®
series.