SAFETY CONCERN 

 
Where personal safety or significant property damage can occur due to a spill, the installation must have a 
redundant backup safety system installed. 

 

WARRANTY 
 

Flowline warrants to the original purchaser of its products that such products will be free from defects in 
material and workmanship under normal use and service in accordance with instructions furnished by Flowline 
for a period of two years from the date of manufacture of such products. Flowline's obligation under this 
warranty is solely and exclusively limited to the repair or replacement, at Flowline's option, of the products or 
components, which Flowline's examination determines to its satisfaction to be defective in material or 
workmanship within the warranty period. Flowline must be notified pursuant to the instructions below of any 
claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product 
repaired under this warranty will be warranted only for the remainder of the original warranty period. Any 
product provided as a replacement under this warranty will be warranted for the full two years from the date of 
manufacture.

 

 
RETURNS 
 

Products cannot be returned to Flowline without Flowline's prior authorization. To return a product that is 
thought to be defective, go to flowline.com, and submit a customer return (MRA) request form and follow the 
instructions therein. All warranty and non-warranty product returns to Flowline must be shipped prepaid and 
insured. Flowline will not be responsible for any products lost or damaged in shipment.

 

 
LIMITATIONS 
 

This warranty does not apply to products which: 1) are beyond the warranty period or are products for which 
the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to 
electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified 
or altered;  4) anyone other than service personnel authorized by Flowline have attempted to repair; 5) have 
been involved in accidents or natural disasters; or 6) are damaged during return shipment to Flowline. Flowline 
reserves the right to unilaterally waive this warranty and dispose of any product returned to Flowline where: 1) 
there is evidence of a potentially hazardous material present with the product; or 2) the product has remained 
unclaimed at Flowline for more than 30 days after Flowline has dutifully requested disposition. This warranty 
contains the sole express warranty made by Flowline in connection with its products. ALL IMPLIED 
WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or 
replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL 
FLOWLINE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND 
INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY 
CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO 
PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF 
OF FLOWLINE. This warranty will be interpreted pursuant to the laws of the State of California. If any portion 
of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other 
provision of this warranty. 

 

For complete product documentation, video training, and technical support, go to flowline.com. 
For phone support, call 562-598-3015 from 8am to 5pm PST, Mon - Fri. 
(Please make sure you have the Part and Serial number available.) 

 
 

Содержание DataLoop LI23 Series

Страница 1: ...I2 ne Inc 10500 Hu 18 Flowline Rights Reser e in USA Data Loop Powere 23 Series umbolt Street Los Inc rved aLoo ed Meters s Quick S Alamitos CA 9072 op Start 20 p 562 598 3015 5 f 562 431 8507 w flowline com QS302100 Rev A A ...

Страница 2: ...ed General Purpose Bar graph Two Solid State Relays LI23 1211 Loop Powered General Purpose Bar graph Two Solid State Relays and 4 20mA Analog Output Model Accessories LM91 1001 Single NEMA Box non windowed 1 8 DIN PC LM91 2001 Dual NEMA Box non windowed 1 8 DIN PC LM92 1002 Single NEMA Box Windowed 1 8 DIN PC LM92 2002 Dual NEMA Box Windowed 1 8 DIN PC LM92 3002 Triple NEMA Box Windowed 1 8 DIN PC...

Страница 3: ...ure to maintain a minimum panel thickness of 0 04 0 25 1 0 mm 6 4 mm to maintain type 4X rating This would equal 0 06 1 5 mm for a steel panel and 0 16 4 1 mm for a plastic panel Remove the Loop Powered Meter s two mounting brackets Back off the two screws so that there is 6 4 mm or less through the bracket Slide the bracket toward the front of the case and remove it Insert the Loop Powered Meter ...

Страница 4: ...talled in bright lighting conditions to reduce the maximum voltage drop to 1 5 V as shown in the following diagram THE LOOP POWERED METER INTERFACE The Loop Powered Meter is factory calibrated to read in milliamps prior to shipment Overview There are no jumpers to set for the meter input selection All setup and programming is performed through the front panel interface After power and input signal...

Страница 5: ...f a digit or character ENTER F3 Use this button to access a menu or to accept a setting or programmed digit character value PROGRAMMING THE LOOP POWERED METER To enter the LI23 series Programming menu press the MENU button With the UP arrow or RIGHT arrow you can scroll through four menu options Input Output Advanced and Display Input This selects the units of operation as well as scaling the disp...

Страница 6: ... hold the RIGHT Arrow button until all digits reset to zero Press the ENTER button at any time to accept a setting or MENU button to exit without saving changes Note the underscore in the graphic below is provided to show which digit would be flashing A Confirm the Operation Scale for the Application Typically the LI23 series must match the operational span of the transmitter mounted on top of or ...

Страница 7: ...accuracy is very good but may not be practical When selecting a decimal point take into account the practical scale for reading the level of liquid To set the Decimal Point 1 Press the MENU button to bring up the SETUP Input screen 2 Press Up Arrow button to bring up SETUP Display screen 3 Press ENTER button to bring up DSPLAY Units screen 4 Press Right Arrow to bring up DSPLAY decpt screen 5 Pres...

Страница 8: ...cm meter etc Please determine the units of operation that you want to appear on the display To set the Units of Operation 1 Press MENU button to bring up the SETUP Input screen 2 Press ENTER button to bring up SCALE Units screen 3 Press ENTER to bring up SCALE Height screen 4 Use the Right Arrow or Up Arrow to change the groups between HEIGHT and VOLUME 5 Press ENTER button to select your group 6 ...

Страница 9: ...n the examples above the 4 mA Empty reading could represent 0 Gallons 0 Feet 0 Inches or 0 0 The 20 mA Full reading could represent 5 000 Gallons 10 00 Feet 120 0 Inches or 100 0 Setting 4mA for an empty tank and 20 mA for a full tank simplifies configuration To set the SCALE function 1 Press MENU button to bring up the SETUP Input screen 2 Press ENTER button to bring up SCALE Units screen 3 Press...

Страница 10: ... value you want to display when the tank is full b To change the value use the UP Arrow to incrementally increase the selected digit and the Right Arrow to move to the next digit c If you are reading the height of the liquid this value will typically be the same value as the Fill Height setting in the Flowline transmitter d If you 11 Press ENTER to save the Display 2 setting and to bring up SAVE s...

Страница 11: ...eature can be enabled or disabled using the Bargraph menu BARGRAPH The value displayed on the bar graph can be the percentage of full scale PV PCT or the percentage of a user programmable range PV To set the Bar Graph 1 Press the MENU button to bring up the SETUP Input screen 2 Press Up Arrow button to bring up SETUP Display screen 3 Press UP Arrow or RIGHT Arrow button three 3 times to bring up D...

Страница 12: ...hich the original purchaser does not follow the warranty procedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowline have attempted to repair 5 have been involved in accidents or natural disasters or 6 are damaged during return shi...

Отзывы: