Troubleshooting UltraPierce by symptom
Delamination or breakage on the part's top surface
Abrasive is not getting to the cutting head before the the water turns on. Increase the
After abrasive on
dwell time.
Delamination or breakage on the surface around the pierced exit hole
Damage at the exit hole is a function of the pressure used to pierce the material—it is not related to
vacuum assist operation. Decrease the pierce pressure.
Clog during normal cutting
• UltraPierce is leaking—this causes insufficient vacuum levels in the cutting head, so that it
cannot draw abrasive properly. Find the leak and repair it.
• Abrasive feed rate it too high—lower the feed rate.
• Check the pinch valve tubing for holes or tears and replace if needed.
Clog during piercing
• Increase the air pressure to 5.5 bar (80 psi) or greater.
• Check the pinch valve tubing for holes or tears and replace if needed.
During calibration, vacuum gauge does not read 0–5 Hg.
The eductor sleeve has worn out—replace the vacuum pump.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 14, 2021 PST
Ancillary option: UltraPierce Vacuum Assist
Содержание MACH 300
Страница 1: ...MACH 300 SYSTEM MANUAL Includes Ancillary Options M 810 REV C en APRIL 2021...
Страница 28: ...View 2 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Страница 29: ...View 3 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Страница 30: ...View 4 View 5 Z axis cover 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Страница 31: ...View 6 Roll around console 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Страница 63: ...2021 Flow International Corp Retrieved from Flow KB on April 13 2021 PST Cutting with Dynamic Waterjet...
Страница 107: ...ANCILLARY OPTIONS For Mach 300...