background image

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Safety 2

Im portant  Safety 

Instructions

SAVE THESE INSTRUCTIONS - This manual contains 

important instructions that should be followed during 

installation, operation, and maintenance of the product.

This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for 

one of the following signal words and be alert to the 

potential for personal injury!

indicates a hazard which, if not avoided, 

will result in death or serious injury.

indicates a hazard which, if not avoided, 

could result in death or serious injury.

indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 

personal injury.
Carefully read and follow all safety instructions in this 

manual and on pump.
Keep safety labels in good condition. Replace missing 

or damaged safety labels.
California Proposition 65 Warning

This product contains chemicals known to 

the State of California to cause cancer or birth defects 

or other reproductive harm.
1.  Know the pump application, limitations, and potential 

hazards.

2.  Do not use in water with fish present. If any oil leaks 

out of the motor it can kill fish.

3.  Disconnect power before servicing.
4.  Release all pressure within system before servicing 

any component.

5.  Drain all water from system before servicing.
6.  Secure discharge line before starting pump. An 

unsecured discharge line will whip, possibly causing 

personal injury and/or property damage.

7.  Check hoses for weak or worn condition before each 

use, making certain that all connections are secure.

8.  Periodically inspect sump, pump and system 

components. Keep free of debris and foreign objects. 

Perform routine maintenance as required. 

9.  Provide means of pressure relief for pumps whose 

discharge line can be shut-off or obstructed.

10.  Personal Safety:

a.  Wear safety glasses at all times when working with 

pumps.

b.  Keep work area clean, uncluttered and properly 

lighted – replace all unused tools and equipment.

c.  Keep visitors at a safe distance from work area.
d.  Make workshop child-proof – with padlocks, master 

switches, and by removing starter keys.

11.  When wiring an electrically driven pump, follow all 

electrical and safety codes that apply.

12.  This equipment is only for use on 115 volt  

(single phase) and is equipped with an approved 

3-conductor cord and 3-prong, grounding-type plug.

Risk of electric shock. Can shock, burn or 

kill. This pump has not been investigated for use in 

swimming pool areas. Pump is supplied with a grounding 

conductor and grounding-type attachment plug. Be sure it 

is connected only to a properly grounded grounding-type 

receptacle.
Where a 2-prong wall receptacle is encountered, it must 

be replaced with properly grounded 3-prong receptacle 

installed in accordance with codes and ordinances that 

apply.
13.  All wiring should be performed by a qualified 

electrician.

14.  Make certain power source conforms to requirements 

of your equipment.

15.  Protect electrical cord from sharp objects, hot 

surfaces, oil, and chemicals. Avoid kinking cord. 

Replace or repair damaged or worn cords  

immediately.

16.  Do not touch an operating motor. Modern motors can 

operate at high temperatures.

17.  Do not handle pump or pump motor with wet hands 

or when standing on wet or damp surface, or in water.

Risk of electric shock. Can shock, burn or 

kill. If your basement has water or moisture on floor, do 

not walk on wet area until all power has been turned off. 

If shut-off box is in basement, call electric company or 

hydro authority to shut-off service to house, or call your 

local fire department for instructions. Remove pump and 

repair or re place. Failure to follow this warning can result 

in fatal electrical shock.
Do not lift pump by power cord.

GPH (LPH) at total feet (m) of lift

Series

HP

(1.5m)

10 

(3m)

15 

(4.6m)

20 

(6.1)

No flow 

at height 

shown 

below

Capacity Gallons(L)/Hour

FPZS50RP

 1/2

3660 

(13855)

3000 

(11356)

2160 

(8176)

960 

(3634)

22 ft 

(6.7m)

Series

HP

Motor 

Full 

Load 

Amps

Branch 

Circuit Req. 

(Amps)

Switch Setting in inches 

(cm)

On

Off

FPZS50RP

1/2

4.1

15

7.5 (19.1)

3 (7.6)

Performance

Electrical & Switch Specifications

Содержание FPZS50RP

Страница 1: ...ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Français Pages 8 12 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 365 6832 Español Paginas 13 19 293 Wright Street Delavan WI 53115 Phone 1 800 365 6832 Fax 1 800 526 3757 flotecwater com 2014 Pentair ...

Страница 2: ...ttered and properly lighted replace all unused tools and equipment c Keep visitors at a safe distance from work area d Make workshop child proof with padlocks master switches and by removing starter keys 11 When wiring an electrically driven pump follow all electrical and safety codes that apply 12 This equipment is only for use on 115 volt single phase and is equipped with an approved 3 conductor...

Страница 3: ... old sump from sump pit NOTICE Remove all sand clay and gravel before installing 5 Place Easy Sump into sump pit Make sure vertical float switch can operate freely inside sump pit 6 Run power cord and piggyback switch up through the correct hole in sump pit cover For parts or assistance call Flotec Customer Service at 1 800 365 6832 Specifications Installation 3 Specifications Power supply require...

Страница 4: ...motor with wet hands or when standing on wet or damp surface or in water 1 Shaft seal depends on water for lubrication Do not operate pump unless it is submerged in water as seal may be damaged if allowed to run dry 2 Motor is equipped with automatic reset thermal protector If temperature in motor should rise switch will cut off all power before damage can be done to motor When motor has cooled sw...

Страница 5: ... Description Qty FPZS50RP 1 Power Cord Assembly 1 PS117 54 TSU 2 Vertical Float Switch Assembly 1 FPS17 66 3 Screw 8 32 x 7 8 4 4 Motor 1 5 Upper Volute 1 PS1 327 6 Screw 8 32 x 1 2 5 7 Impeller 1 PS1 286 8 Lower Volute 1 PS1 326 9 Screw 8 x 5 8 coarse thread Sheet Metal Screw 6 10 Check Valve 1 FP0026 10 PLASTIC SERIES 1 2 3 4 5 6 7 8 9 10 ...

Страница 6: ...efective float switch Replace float switch Restricted discharge obstacle or ice in piping Remove pump and clean pump and piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and clean the intake screen and the impeller Pump operates but delivers little or no water Low line voltage If voltage under recommended minimum check size of wiring from main switch on property ...

Страница 7: ...age pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Model Warranty Per...

Страница 8: ...ipement inutiles c Les visiteurs doivent se tenir à une distance sécuritaire de la zone de travail d Poser des cadenas pour s assurer que les enfants ne pourront pas pénétrer dans l atelier de travail Poser aussi un interrupteur général et enlever les clés des démarreurs 11 Lorsque l on câble une pompe électrique observer tous les codes de sécurité et de l électricité applicables 12 Cet équipement...

Страница 9: ... La pompe Easy Sump comporte déjà toute la tuyauterie nécessaire jusqu au clapet antiretour Le système comprend la pompe le tuyau en PVC le clapet antiretour et l interrupteur à flotteur vertical Outils articles nécessaires Tournevis ruban à mesurer scie à métaux et attaches de câbles 1 Débrancher la pompe de puisard existante et placer le cordon d alimentation et l interrupteur superposable loin ...

Страница 10: ...ucher à la pompe ni au moteur de la pompe lorsqu on a les mains humides ou lorsqu on se tient debout sur une surface mouillée humide ou dans l eau 1 Le joint de l arbre dépend de l eau pour son graissage Ne pas utiliser la pompe si elle n est pas immergée dans l eau sinon son joint sera endommagé si la pompe fonctionne à sec 2 Le moteur est équipé d un protecteur thermique à réarmement automatique...

Страница 11: ...astiques Si le moteur tombe en panne Replacer la pompe No ilustré Réf Désignation Qté FPZS50RP 1 Ensemble de cordón électrique 1 PS117 54 TSU 2 Assemblée de l interrupteur à flotteur 1 FPS17 66 3 Vis 8 32 x 7 8 4 4 Moteur 1 5 Volute supérieure 1 PS1 327 6 Vis 8 32 x 1 2 5 7 Impulseur 1 PS1 286 8 Volute inférieure 1 PS1 326 9 Vis 8 5 8 fil vis feuille métal grossière 6 10 Capet anti retour 1 FP0026...

Страница 12: ...tueux Remplacer l interrupteur du flotteur La pompe refuse de s arrêter Interrupteur du flotteur défectueux Remplacer l interrupteur du flotteur Diminution du refloulement obstruction ou glace dans la tuyauterie Déposer la pome et nettoyer la pompe et la canalisation Entrave trop longue Raccourcir l entrave La crépine d aspiration est obstruée Déposer la pompe et nettoyer la crépine d aspiration a...

Страница 13: ...té utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois ...

Страница 14: ... 11 Cuando instale el cableado de una bomba accionada eléctricamente siga todos los códigos eléctricos y de seguridad que correspondan 12 Esta bomba solamente se puede usar con corriente de 115 voltios monofásica y está equipado con un cordón aprobado de 3 conductores y 3 clavijas del tipo de puesta a tierra Risque de secousses électriques Pouvant causer des brúlures voire la mort No se ha comprob...

Страница 15: ... interruptor de flotador Los modelos provistos de interruptores verticales necesitan un poco de ensamblaje Instalación La bomba Easy Sump viene con plomería instalada hasta la válvula de retención El sistema incluye la bomba el tubo en PVC la válvula de retención y el interruptor de flotador vertical Se necesita Destornillador cinta métrica sierra para metales ligaduras de cable 1 Desenchufe la bo...

Страница 16: ...cionamiento Risque de secousses électriques Pouvant causer des brúlures voire la mort No manipule la bomba o el motor de la bomba con las manos mojadas o cuando esté parado en suelo húmedo mojado o en el agua 1 La junta del eje depende del agua para su lubricación No haga funcionar la bomba a menos que esté sumergida en agua ya que la junta puede dañarse si se hace trabajar en seco 2 El motor está...

Страница 17: ...so Reemplace la bomba No ilustrado Ref Descripción Cant FPZS50RP 1 Tornillo de abrazadera de cordon 1 PS117 54 TSU 2 Unidad del interruptor de flotador vertical 1 FPS17 66 3 Tornillo 8 32 x 7 8 1 4 Motor 4 5 Voluta superior 1 PS1 327 6 Tornillo 8 32 x 1 2 1 7 Impulsor 5 PS1 286 8 Voluta inferior 1 PS1 326 9 Screw 8 5 8 hilo tornillo de hoja metal gruesa 1 10 La válvula de retención 6 FP0026 10 1 2...

Страница 18: ...retención El interruptor del flotante está fallado Reemplace el interruptor del flotante La bomba no se desconecta Interruptor defectuoso del flotante Reemplace el interruptor del flotante Descarga obstruida obstáculos o hielo en las tuberías Retire la bomba y limpie la bomba y la tubería El brazo del flotante es demasiado largo Acorte el brazo del flotante El movimiento del flotante está obstruid...

Страница 19: ...FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas locales que correspon...

Страница 20: ......

Отзывы: