Flotec FPSE3500A Скачать руководство пользователя страница 2

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Safety / Specifications / Performance / Installation

2

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. 

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

The label 

NOTICE

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

1. Read this manual carefully. Failure to follow these

instructions could cause serious bodily injury and/or
property damage.

2. Check your local codes before installing. You must

comply with their rules. 

3. Vent sewage or septic tank according to local codes.

4. Do not install pump in any location classified as 

hazardous by National Electrical Code, ANSI/NFPA
70-1990.

Hazardous voltage. Can shock, burn or

cause death. 

During operation, the pump is in water. 

To avoid fatal shocks, proceed as follows if pump needs
servicing:

5A. Disconnect power to outlet box before unplugging

pump.

5B. Take extreme care when changing fuses. Do not

stand in water or put your finger in fuse socket.

5C. Do not modify cord and plug. When using cord and

plug, plug into a grounded outlet only. When wiring
to a system control, connect pump ground lead to
system ground.

6. Do not run pump dry. Dry running can overheat

pump, (causing burns to anyone handling it) and will
void warranty. 

7. Motors can operate at high temperatures. To avoid

burns when servicing pump, allow it to cool for 
20 minutes after shut-down before handling it.

8. In normal service, motor should not need oiling.

Motor has been filled at the factory with a 
special oil.

9.

The oil-filled motor was not designed for use in
water containing fish. Do not use this pump in
water with fish present. If any oil leaks out of the
motor it can kill fish.

Installation

Pump must be level when operating.

If

motor is tilted, internal start/run switch may overheat and
damage motor.

Risk of electrical shock.

Can burn or kill.

Do not lift pump by power cord. See “Cord Lift Warning”
on Page 4. Do not hang pump from discharge pipe or
power cord. 

NOTICE:

Do not reduce size of discharge pipe or hose

below 1-1/4" diameter. If discharge is too small, pump
will overheat and fail prematurely.

NOTICE:

This unit is not designed as a waterfall or fountain

pump, or for applications involving salt water or brine! Use
with waterfalls, fountains, salt water or brine will void 
warranty.
1. Install the pump on a solid, level foundation, or in a

sump pit constructed of tile, concrete, steel or
plastic. The  recommended minimum diameter of the
sump pit is 14" (36cm) diameter and  the minimum
recommended depth is 30" (76cm). Check local
codes for approved materials.

NOTICE:

Pump should not be installed on clay, earth

or sand surfaces. Clean the area around the pump of
small stones and gravel which could clog the pump.
Keep the pump inlet screen clear.

2. Thread a 2" discharge pipe into the  pump 2" NPT

discharge port. Be careful to avoid stripping or
crossing threads.

GPH (LITERS) AT DISCHARGE FT. OF HEAD (m)

Model

5 (1.5m)

10 (3m)

15 (4.6m)

Max Lift (No Flow)

FPSE3500A

4800 (18,170)

3200 (12,113)

1800 (6,814)

18' (5.5m)

Performance

Individual Branch Circuit 

Dual Element Time 

Model

H.P.

Voltage

Required (Amps)

Delay Fuse Amps

FPSE3500A

1/2

115

15

15

Specifications

Содержание FPSE3500A

Страница 1: ...2 English Pages 2 5 Installation Fonctionnement Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Français Pages 6 9 Instalación Operación Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 365 6832 Español Paginas 10 13 2010 FP829 7 9 10 FPSE3500A P O Box 342 Delavan WI 53115 Phone 1 800...

Страница 2: ...nning can overheat pump causing burns to anyone handling it and will void warranty 7 Motors can operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling it 8 In normal service motor should not need oiling Motor has been filled at the factory with a special oil 9 The oil filled motor was not designed for use in water containing ...

Страница 3: ...rge pipe about 1 2 2 5 5 1cm above pump discharge connection but below check valve to prevent airlocking the pump 7 Insert the float switch piggy back plug into a properly grounded outlet and the pump plug into the piggy back plug 8 Check the installation by observing the pump operation through one complete cycle Make sure that no parts of the assembly interfere with the float switch Risk of flood...

Страница 4: ...ing 4 If overload trips frequently check for cause It could be a stuck impeller wrong low voltage or electrical failure in motor If an electrical failure in the motor is suspected have it serviced by a competent repairman Pump is permanently lubricated No oiling or greasing is required Service Hazardous voltage Can shock burn or cause death Before removing pump from basin for service always discon...

Страница 5: ...del FP0S1775A Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST Back up Sump Pump System Model FP2800DCC 4 Submersible Well Pumps 1 2 HP Submersible Sump Pumps 3 Years 1 3 HP Sump Pump Models FPSC2200A 10 and FPSC2250A 10 Pre Charge Water System Tank FP7100 Series 1 2 HP Sump Pump Models FPSC3200A 10 and FPSC3250A 10 5 Years Submersible Solids...

Страница 6: ...ur éviter les brûlures lors des interventions sur la pompe la laisser refroidir après la mise à l arrêt pendant 20 minutes avant de la manipuler 8 Lors d une utilisation normale le moteur ne devrait pas avoir besoin d huile il a été lubrifié en usine avec une huile spéciale 9 Le moteur rempli d huile n est pas conçu pour être utilisé dans des eaux contenant des poissons Ne pas utiliser cette pompe...

Страница 7: ...ntre 2 5 et 5 1 cm 1 et 2 po au dessus du raccord de refoulement de la pompe mais sous le clapet de non retour pour empêcher la formation de bouchons d air dans la pompe 7 Introduire la prise multiple de l interrupteur à flotteur dans une prise de courant adéquatement mise à la terre puis brancher la prise de la pompe dans la prise multiple de l interrupteur à flotteur 8 Vérifier l installation en...

Страница 8: ...t de manipuler la pompe ou le moteur 2 Vérifier si la tension est bien présente 3 Vérifier si le niveau du liquide est suffisamment haut pour activer le contact ou la commande 4 Vérifier si le trou de ventilation de 4 7 mm 3 16èmes de pouce du tuyau d évacuation n est pas bouché 5 Vérifier un blocage de la crépine d entrée du rotor du clapet de non retour ou du tuyau d évacuation 6 Le disjoncteur ...

Страница 9: ...0S4100X 2 ans Pompe de récupération des eaux condensées modèle FPCP 20ULST Système de pompage de secours de puisard de soutien modèle FP2800DCC Pompes de puits submersibles de 10 2 cm 4 po Pompes de puisard submersibles de 1 2 CV 3 ans Pompes de puisard submersibles de 1 3 CV modèles FPSC2200A 10 et FPSC2250A 10 Réservoir préchargé de système d eau gamme FP7100 Pompes de puisard submersibles de 1 ...

Страница 10: ...l funcionamiento en seco sobrecalienta la bomba puede causar quemaduras a quien la manipule El sobrecalentamiento invalida la garantía 7 Los motores pueden funcionar a temperaturas altas Para evitar quemaduras al prestar servicios a la bomba déjela enfriar 20 minutos después de desconectarla y antes de manipularla 8 En servicio normal no es necesario aceitar el motor El motor ha sido lubricado en ...

Страница 11: ...mba pero por debajo de la válvula de reten ción para evitar la creación de bolsas de aire en la bomba 7 Introduzca el enchufe superpuesto del interruptor de flotador en un tomacorriente debidamente puesto a tierra y el enchufe de la bomba en el enchufe superpuesto 8 Verifique la instalación observando el funcionamiento de la bomba a través de un ciclo completo Asegúrese de que ninguna pieza de la ...

Страница 12: ...e servicio de su localidad 1 Si se levanta o sujeta la bomba por el cordón de alimentación eléctrica puede dañar el cordón y las conexiones 2 El cordón se puede salir dejando al descu bierto los alambres desnudos con la posi bilidad de incendio o choque eléctrico 3 Si levanta o sujeta la bomba por el cordón anulará la garantía 4 Use el anillo de elevación o la manija situada en la parte superior d...

Страница 13: ...0F360AC Bombas de sumidero sumergibles INTELLIPUMP de 1 3 HP Modelo FP0S1775A Bomba para cubiertas de piscina Modelo F0S1790PCA 2 años Bomba para todo uso Modelo FP0S4100X Bomba de condensado Modelo FPCP 20ULST Sistema de bomba de sumidero de respaldo Modelo FP2800DCC Bombas de pozo sumerg bles de 4 Bombas de sumidero sumergibles de 1 2 HP 3 años Bombas de sumidero de 1 3 HP Modelos FPSC2200A 10 y...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ......

Отзывы: