background image

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Shaded-pole motor is oil filled and sealed
for cooler running. Sleeve bearings on motor shaft never
need lubrication. Automatic reset thermal protection. Not
designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge:

Plastic Models............1-1/4" FNPT / 1-1/2" MNPT
Cast Iron Models ...............................1-1/2" FNPT

NOTICE:

Do not reduce size of discharge pipe or

hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.

NOTICE:

This unit is not designed for applications

involving salt water or brine! Use with salt water or
brine will void warranty.
Pump water only with this pump.
Do not use where water recirculates.
Not designed for use as a swimming pool 
drainer.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more infor-
mation, see your retailer, call Flotec customer 
service at 1-800-365-6832 or visit our website at
www.flotecwater.com.
1. Know the pump application, limitations, and

potential hazards.

2.

Do not use in water with fish present.

3. Disconnect power before servicing.
4. Release all pressure within system before servic-

ing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and prop-

erly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volt (sin-
gle phase) and is equipped with an approved 
3-conductor cord and 3-prong, grounding-type
plug.

GPH (LPH) AT TOTAL FEET (M) OF LIFT

Motor

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

FP0S1800A

1/4

2280

1620

660

18 Ft.

FP0S1800LTS

(8 631)

(6 132)

(2 498)

(5.5M)

FP0S2400A

1/3

2760

2160

1410

20 Ft.

FP0S2450A  

(10 448)

(8 176)

(5 337)

(6.1M)

FP0S3200A 

1/2

3200

2700

2000

24 Ft.

FP0S3250A 

(12 113) (10 220)

(7 571)

(7.3M)

FPSC2200A 

1/3

2800

2200

1400

20 Ft.

FPSC2250A 

(10 599)

(8328)

(5299)

(6.1M)

No flow 

at height

shown

below

Individual

Motor

Branch

*Switch Setting

Motor Full Load

Circuit

in inches (mm)

Series

HP

Amps

Req.(Amps)

On

Off

FP0S1800A

1/4

8.5

15

11

3

4

"(298) 4

1

2

"(114)

FP0S1800LTS

1/4

8.5

15

6

1

4

"(159)

3"(76)

FP0S2400A

1/3

9.0

15

13"(330)

6"(152)

FP0S3200A

1/2

5.5

15

13"(330)

6"(152)

FPSC2200A

1/3

9.0

15

13"(330)

6"(152)

FP0S2450A

1/3

9.0

15

8"(203)

4"(102)

FP0S3250A

1/2

6.0

15

8"(203)

4"(102)

FPSC2250A

1/3

9.0

15

8"(203)

4"(102)

Содержание FP0S2450A-08

Страница 1: ...stallation Operation Parts For further operating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant...

Страница 2: ...application limitations and potential hazards 2 Do not use in water with fish present 3 Disconnect power before servicing 4 Release all pressure within system before servic ing any component 5 Drain...

Страница 3: ...p pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint com pound on plastic pipe Pipe joint compound can attack plastics 4 Install di...

Страница 4: ...frozen discharge pipe etc could cause cycling 3 Pump will not remove all water If operating a pump manually and suddenly no water comes out of the discharge hose shut off the unit immediately The wate...

Страница 5: ...A Tethered Float Switch Assembly 1 FP18 15BD FP18 15BD 4B Vertical Float Switch Assembly 1 FPS17 66 FPS17 66 5 Screw 8 32x7 8 Hex Head 4 U30 951PS U30 951PS U30 951PS 6 Motor 1 7A Volute Upper 1 PS1 3...

Страница 6: ...oat switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle or ice in piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and cl...

Страница 7: ...installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials...

Страница 8: ...lotecwater com 1 Avant tout il faut conna tre les applications de la pompe ces limites et les dangers potentiels que pr sente son utilisation 2 Ne pas utiliser pour pomper de l eau dans laquelle se tr...

Страница 9: ...uisse avant le plus grand d gagement possible 3 Il ne faut pas poser la pompe sur une surface en argile en terre ou sablonneuse Enlever les petites pierres et le gravier du puisard qui risqueraient de...

Страница 10: ...t fonc tionner la pompe manuellement et que brusque ment l eau ne coule plus par son tuyau de refoule ment arr ter imm diatement la pompe Le niveau de l eau est probablement tr s bas et la pompe s est...

Страница 11: ...Interrupteur flotteur cordon 1 FP18 15BD FP18 15BD 4B Interrupteur flotteur vertical 1 FPS17 66 FPS17 66 5 Vis t te hexagonale n 8 32 x 7 8 de pouce 4 U30 951PS U30 951PS U30 951PS 6 Moteur 1 7A Volut...

Страница 12: ...upteur du flotteur d fectueux La pompe refuse de Interrupteur du flotteur Remplacer l interrupteur du flotteur s arr ter d fectueux Diminution du refoulement D poser la pompe et nettoyer la pompe et l...

Страница 13: ...etenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pannes de fonctionnement caus es par la corrosion la rouille ou au...

Страница 14: ...Flotec 1 800 365 6832 o visite nuestro sitio en Internet www flotecwater com 1 Inf rmese sobre la aplicaci n limitaciones y posi bles riesgos de la bomba 2 No usar en agua en donde haya peces 3 Descon...

Страница 15: ...a bomba AVISO No use obturador de juntas de tuber a en las tuber as de pl stico El obturador de juntas de tuber a puede da ar el pl stico 4 Instale la tuber a de descarga Use tuber as de pl sti co r g...

Страница 16: ...ra de descarga apague la unidad inmediata mente Probablemente el nivel del agua es muy bajo y la unidad ha dejado de cebar Riesgo de choque el ctrico Antes de inten tar revisar porque la bomba ha deja...

Страница 17: ...4A Unidad del interruptor de flotador anclado 1 FP18 15BD FP18 15BD 4B Unidad del interruptor de flotador vertical 1 FPS17 66 FPS17 66 5 Tornillo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS U30 9...

Страница 18: ...flotante est fallado Reemplace el interruptor del flotante La bomba no se Interruptor defectuoso Reemplace el interruptor del flotante desconecta del flotante Descarga obstruida Retire la bomba y lim...

Страница 19: ...do a instalaci n funcionamiento manteni miento o almacenaje incorrectos ni a ninguna otra cosa que no sea su aplicaci n uso o servicio normales incluyendo pero no limitado a fallas operacionales causa...

Страница 20: ......

Отзывы: