Flotec Floodmate 7000 Скачать руководство пользователя страница 2

2

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this sym-

bol on your pump or in this manual, look for one of the fol-

lowing signal words and be alert to the potential for personal
injury!

warns about hazards that will cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that can  cause serious

personal injury, death or major property damage if ignored.

warns about hazards that will or can cause

minor personal injury or property damage if ignored.
The label 

NOTICE

indicates special instructions which are impor-

tant but not related to hazards.
Make sure installation complies with all electrical / plumbing
codes.

Hazardous Voltage. Can cause serious or fatal

electrical shock. Disconnect power to pump before servicing.

If floor is wet, disconnect power at main electrical service

before  walking on it. Do not stand in water or touch metal

surfaces when switching circuit breaker or removing/installing
fuses.

Pump is equipped with a three-prong, grounding cord and

plug. Do not modify cord or plug. Plug this unit into a 115V

outlet, on an individual branch circuit, with a Class A, 10 amp
GFCI (Ground Fault Circuit Interrupter).

Do not use in explosive environments. Pump

water only with this pump. Inspect sump, pump and system
components monthly. Keep free of debris and foreign objects.
Perform routine maintenance as required.

Risk of flooding. If a flexible discharge hose

is used, pump may move around in sump when motor
starts. 
If it moves far enough so that switch hits side of sump,
switch may stick and prevent pump from starting. Make sure
pump is secured so it cannot move around in sump.
Electrically powered sump pumps normally give many years of
trouble-free service when correctly installed, maintained, and
used. However, unusual circumstances (interruption of power to
the pump, dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in the pump, etc.)
may prevent your pump from functioning normally. To prevent
possible water damage due to flooding, consult your dealer about
installing a secondary sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting Chart” in this
manual for information about common sump pump problems and
remedies. For more information, see your retailer, call Flotec cus-
tomer service at 1-800-365-6832 or visit our website at
www.flotecwater.com.

NOTICE 

This unit is not designed for applications involving salt

water or brine! Use with salt water or brine will void warranty.

SPECIFICATIONS

Power Supply Required. ............................................115V, 60HZ.
Liquid Temperature Range ....................................77°F Maximum
Individual Branch Circuit Required (minimum) .............10.0 Amps
Motor Full Load (maximum) ............................................7.5 Amps
Discharge (Insert for 1-1/4” also included).......1-1/2" Slip Adapter

NOTICE 

Do not use where fish are present. Any leakage of oil

from the motor into the water can kill fish.
Not designed for use as a swimming pool drainer.

Do not use where water recirculates.

PERFORMANCE

OPERATION

Pump is equipped with an automatic float switch which starts
pump when water level reaches 10"-12". Pump automatically
turns off when level drops to 4" - 6". 

GENERAL GUIDELINES 

Sump should be at least 18" deep. Inside diameter of sump
should be at least 14".
Check Valve is built-in. If necessary to allow flowback from dis-
charge pipe to sump:
• Drill a 1/8" diameter hole in the discharge pipe 2” above the

pump. Pump should be installed below the basement floor
level.

Discharge Pipe: Pump is supplied with flexible connector that fits
1-1/2” PVC or ABS pipe. Adapter insert allows use of 1-1/4” PVC
or ABS pipe. PVC or ABS adapters may be purchased to fit other
discharge pipe sizes.

ELECTRICAL

Hazardous voltage. Can cause severe or fatal

electrical shock. Pump is supplied with a grounding conductor
and grounding-type attachment plug. To reduce risk of electric
shock, be certain that it is connected only to a properly ground-
ed, grounding type receptacle.
Plug this unit into a 115V outlet, on an individual branch circuit,
with a Class A, 10 amp GFCI (Ground Fault Circuit Interrupter).
For installation of such a circuit, consult a licensed electrician.

ELECTRICAL SERVICE

AC power outlets should be on a separate 10 amp individual
branch circuit; 115V, AC, 60 cycles, and located within 8 ft. of
sump. Ground terminal on pump cord plug is provided for your
protection. DO NOT REMOVE!

PUMP INSTALLATION

1. Remove debris and foreign material etc., from sump to pre-

vent clogging.

2. Place pump on smooth, level surface. Use building blocks or

bricks to elevate pump screen a minimum of  2" above mud,
sand or loose stones.

3. Locate pump in center of pit so pump housing and float con-

trol will not come in contact with side of pit and create opera-
tional problems.

4. Slip connector hose over pump discharge. Install and tighten

first clamp.

5. Place second clamp loosely over connector hose.
6. Slip connector hose over discharge pipe. Clamp hose tightly

with second clamp. Run discharge piping to nearest outlet,
depending on local plumbing codes. Discharge piping should
be as short as possible to reduce pipe friction losses.
Discharge pipe diameter should be equal to or larger than dis-
charge size of pump. Smaller pipe diameters will restrict
capacity of pump and reduce performance.

7. Securely anchor flexible discharge line if used. If line is not

secure, pump may tip during operation.

Total Lift in Feet

5'

10'

15'

20'

25'

Capacity in GPH

6000 5040 3840

2340

0

Содержание Floodmate 7000

Страница 1: ...ges 2 4 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 5 7 Instalaci n Operaci n Piezas...

Страница 2: ...ly Required 115V 60HZ Liquid Temperature Range 77 F Maximum Individual Branch Circuit Required minimum 10 0 Amps Motor Full Load maximum 7 5 Amps Discharge Insert for 1 1 4 also included 1 1 2 Slip Ad...

Страница 3: ...ardous Voltage Can cause serious or fatal electrical shock Disconnect power to pump before servicing SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Motor does not run Blown fuse Replace Tripped circuit Re...

Страница 4: ...ontact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For...

Страница 5: ...t de d rivation individuel requis minimum 10 0 amp res Charge totale sur le moteur maximum 7 5 amp res Refoulement garniture pour 1 1 4 pouce aussi incluse adaptateur coulissant de 1 1 2 pouce AVIS Ne...

Страница 6: ...nsion est ad quate LISTE DES PI CES DE RECHANGE TABLEAU DE RECHERCHE DES PANNES Tension dangereuse Risque de blessures ou de secousses lectriques mortelles D brancher le courant avant d intervenir sur...

Страница 7: ...s d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fins...

Страница 8: ...ratura del l quido 77 grados F m ximo Requiere un ramal individual m nimo 10 0 amperios Carga total del motor m ximo 7 5 amperios Descarga tambi n incluye inserci n para 1 1 4 Adaptador de deslizamien...

Страница 9: ...LAS Tensi n peligrosa Puede ocasionar choques el ctricos graves o fatales Desconecte la corriente el ctrica hacia la bomba antes de realizar trabajos de reparaci n o mantenimiento S NTOMA PROBABLE S C...

Страница 10: ...tamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes...

Страница 11: ......

Страница 12: ......

Отзывы: