background image

User manual                                       FLORIDA stove                                             Creina d.d.

3.1.

Ignition procedure

o

Open both primary and secondary air-inlet 
regulators (see picture bellow)  

o

Fully open flue by-pass device (if present).

o

Open the firedoor.

o

After you have put in several ignition material 
(thin wood, ignition cubes, scrambled paper…)
into combustion chamber, insert 2-3 pieces of 
firewood (chopped) on top of it. Please fill 
stove with care to avoid potential damage.

o

Ignite the ignition material and close the 
firedoor.

o

After stove heats up (it usually takes up from 5 
to10 minutes), close primary regulator.

o

Heat output is regulated by opening or closing 
secondary air-inlet regulator.

o

Nominal heat output (8 kW), is generated 
when:

o

primary regulator is set to fully closed

o

secondary regulator is set to fully open

o

there is an aprox. 2,5 kg of firewood inside
of stove

o

draught is at 12 Pa.

o

Some of the air, which is heated up inside of 
stove, is guided through the channels inside 
the stove, onto the firedoor glass, where it 
performs a cleaning (of the glass) (air brush 
cleaning principle). 

Attention: 

Certain types of stoves require 

somewhat longer ignition phase, until there is 
enough negative pressure (draught) for the stove 
to work on its own. When this is the case, use 
smaller, dried-up logs. Afterwards you can use 
bigger logs.
If firedoor is open during ignition phase, strong 
draught can cause fire to blaze up. High flames 

start to pound the firedoor glass, thus sooting it or 
even damaging it.

3.2.

Heating

o

Maximum capacity of the stove is 2,5 kg of 
firewood per hour.

o

Leave the fresh air connection flap (if present) 
open.

o

Fire intensity regulate with secondary air-inlet 
regulator.

o

For flue gases to be able to pass by, flue 
damper should never be fully closed.

o

Also, by closing the flue damper, you could 
cause bigger negative pressure inside the 
stove , which might damage the stove 
(overheating).

3.3.

Loading firewood

o

Fully open flue-damper (is present).

o

When opening firedoor, always use the 
enclosed protection gloves.

o

Open door slowly. 

o

Remember that maximum capacity is 2,5 kg of 
firewood per hour.

o

Close the firedoor.

o

Close the flue-damper (if present) to its 
operating position. 

o

Always keep the fire under control, to prevent 
possible fire accidents. Pay special attention if 
children are around.

4. CLEANING THE STOVE

4.1.

Warnings 

o

Never use water for fire extinction.

o

Cleaning should only be performed when stove
is fully cooled down. Remember - embers 
could remain in ashes, hours after the fire has 
been extinguished.

o

When cleaning, always wear protection gloves.

o

Open firedoor

o

Remove debris from combustion chamber.

o

Glass should be cleaned with special cleaning 
agent. (contact your local stove-supplier, 
regarding those cleaning agents).

o

If stove is being used properly, stove glass 
should remain clean (There is always a 
possibility that not all of conditions, for stove to
work properly, were met (some of the firewood 
might be wet, chimney conditions not perfect 
etc.), therefore glass might still soot up.

 V2.0                                                 Lokaterm

™ 

© 06/06                                                 page  5

secondary regulator

opened out

closed in

primary regulator

opened out

closed in

Содержание Lokaterm

Страница 1: ...CREINA d d Mirka Vadnova 8 4000 KRANJ Tel 04 20 13 350 Fax 04 20 13 363 E mail INFO CREINA SI www lokaterm com www creina si User manual for FLORIDA stove ...

Страница 2: ...functionality with simplified regulation 4 3 INITIAL IGNITION 4 3 1 Ignition procedure 5 3 2 Heating 5 3 3 Loading firewood 5 4 CLEANING THE STOVE 5 4 1 Warnings 5 5 BREAKDOWNS AND CAUSES 6 5 1 Warnings 6 6 WARRANTY 6 6 1 General warranty conditions 6 6 2 Regulations 7 LOKATERM Tel 386 0 4 20 13 350 Creina d d Fax 386 0 4 20 13 363 Ulica Mirka Vadnova 8 e mail info creina si 4000 Kranj Website www...

Страница 3: ... suitable for burning natural firewood ex beech birch wood briquettes and briquettes made of brown coal Beech has one of the best caloric values among firewood and in addition it burns cleanly if stored properly Freshly chopped firewood has to be dried usually from 12 to 18 months prior to use preferably in open space protected from rain Moisture content in firewood should not exceed 20 Beech birc...

Страница 4: ...e primarily of sheetmetal and has a closed combustion chamber o Stove can be placed anywhere in the room along the wall in the corner etc as long as ground is flat No concession is needed for the stove installation o Our stove gives the comfort of having a fireplace in your home by providing clean combustion and room heating 2 1 Increased functionality with simplified regulation o When stove is op...

Страница 5: ... damaging it 3 2 Heating o Maximum capacity of the stove is 2 5 kg of firewood per hour o Leave the fresh air connection flap if present open o Fire intensity regulate with secondary air inlet regulator o For flue gases to be able to pass by flue damper should never be fully closed o Also by closing the flue damper you could cause bigger negative pressure inside the stove which might damage the st...

Страница 6: ...d according to modern technical principles o comply with highest requirements from EN 13240 standard o are constructed from quality materials that are under constant quality supervision o are handled with care during entire manufacturing process o are sophisticated technical devices if installed correctly and according to installation specification Usual wear can be o changes of coating colour due...

Страница 7: ... state the model type and its factory number located on sticker on back of the stove Warranty service is handled by a trained professional who repairs or replaces compromised components free of charge If necessary whole stove can be replaced Repair specialist decides whether or not the stove can be repaired on site or has to be taken back to repairshop Usually it is performed on location where the...