35
IE
GB
Trouble Shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage not on
Check plug socket, cable, line
and plug, where appropriate,
have repaired through electrical
specialist
On/Off switch (
A
17)
defective
Repair by Service Centre
Worn carbon brushes
Defective motor
Device runs with in-
terruptions
Power cable is damaged
Check the cable and have it
changed by the Service Centre
if necessary
Internal loose electrical
connection
Repair by Service Centre
On/Off switch (
A
17)
defective
Blades become hot
Blades (
A
1) are blunt
Have the blades (
A
1)
sharpened or replaced (Service
Centre)
Blades (
A
1) are notched
Have the blades (
A
1) checked
or replaced (Service Centre)
Too much friction due to
lack of lubrication
Oil the blades (
A
1)