Electrical safety
85.
All electrical maintenance and repairs are to be carried out by qualified persons only.
86.
CAUTION - Line terminals may be alive when main switch is in the off position. Disconnect the machine
completely before performing any maintenance or repairs.
87.
WARNING - DO NOT operate the machine with any electrical panels open.
88.
WARNING - The controls on the SAT480 Generation3 include an over load device. It is there to protect the
controls and motor from irreparable damage. If it trips it indicates a problem. (i.e.; undersize power lead or
poor power to your power supply). Refer earlier in this manual for recommendations on power leads. Rectify
the problem or decrease load on the Satellite 480 by using tooling with more surface area, or place weights
supplied on the brackets on handle for this purpose.
89.
Continuing to use the SATELLITE 480 when constant tripping occurs, VOIDS THE WARRANTY!
90.
Never operate machine in the rain or if heavy moisture is present.
91.
The overload is there to protect you and the machine from harm. DO NOT bypass or adjust the over load in
any way. If it is faulty, only replace with original part that is identical to the faulty one.
92.
Never bypass over current devices in this machine.
93.
Never connect or disconnect power cables with voltage present or while under load.
94.
Disconnect all power connections and observe lock out / tag out procedures before attempting to carry out
any maintenance or repair on any equipment.
95.
Avoid any contact with any rotating parts or driven parts.
96.
Never use equipment that has not been tested and tagged (including cords).
97.
Before connecting the machine to power, check the condition of all power leads and cables on, or used in
conjunction with the machine. DO NOT USE it if any faults, cuts, wear marks,
etc…
Get qualified persons to
repair and re-tag it as required by regulations in your country.
98.
Connect machine to suitable power outlet. Only use heavy duty power lead suitable for high current use
(preferably 2.5 mm2 cable), no longer than 15 meters.
99.
If no power is available within the specified distance have a qualified person install a suitable power outlet
closer to your work. Alternatively use 4 mm² cable for up to 40 meters.
100.
Do not operate SATELLITE 480 with any covers or doors removed or open.
Содержание Satellite 480 Generation3
Страница 16: ...Page15 SATELLITE 480 Generation3 Floorex Products 1800 356 673 Wiring Diagram ...
Страница 17: ...SATELLITE 480 Generation3 Page 16 1800 356 673 Floorex Products Main Machine Breakdown ...
Страница 18: ...Page17 SATELLITE 480 Generation3 Floorex Products 1800 356 673 Handle Breakdown ...
Страница 19: ...SATELLITE 480 Generation3 Page 18 1800 356 673 Floorex Products Disk Breakdown ...
Страница 20: ...Page19 SATELLITE 480 Generation3 Floorex Products 1800 356 673 Handle Lock Breakdown ...
Страница 21: ...SATELLITE 480 Generation3 Page 20 1800 356 673 Floorex Products Motor Breakdown SE02 ...
Страница 22: ...Page21 SATELLITE 480 Generation3 Floorex Products 1800 356 673 Axle Breakdown G3 170 ...
Страница 23: ...SATELLITE 480 Generation3 Page 22 1800 356 673 Floorex Products Screen Breakdown 103 ...
Страница 24: ...Page23 SATELLITE 480 Generation3 Floorex Products 1800 356 673 Shroud Breakdown ...
Страница 25: ...SATELLITE 480 Generation3 Page 24 1800 356 673 Floorex Products SP Plug Breakdown for SP machines only ...
Страница 26: ...Page25 SATELLITE 480 Generation3 Floorex Products 1800 356 673 SP Drive Boss Breakdown for SP machines only ...
Страница 27: ...SATELLITE 480 Generation3 Page 26 1800 356 673 Floorex Products SP Shrouds Breakdown for SP machines only ...