background image

DM-2780 Safety & Operators Manual 

1800 FLOOREX 

PAGE 6.                      1800 356 673 

9. 

Switch the Filter cleaning switch on for 20-30 seconds prior 
to operating if the filter is not clean.  

a.  This can be switched off after the 20-30 

seconds but also can be left on during 
vacuum operation.  

b.  Leaving the filter cleaning on during vacuum 

operation is optional. 

c.  The filter cleaning does clean the filter a little 

whilst the motors are on, but not as effective 
as when the vacuum motors are off.  

10.  Switch the vacuum motors on using the toggle switches. 

There is often no need to run all motors especially if the 
tool it is connected to is fairly small like a hand grinder or 
even a 

Meteor™ 250 or a Satellite™ 480 and Satellite™ 

650. 

11.  Use both motors when using a wand and floor tool to clean 

the floor. 

12.  The Head can be lowered using the handle lever and 

locked in place using the locks on either side. 

13.  WARNING!  Breathable silica may be generated by use 

and maintenance of this the Dust Extractor. Silica can 
cause severe and permanent lung damage, cancer, and or 
other serious diseases. Do not breathe the dust. Do not rely 
on your sight or smell to determine if dust is in the air. Silica 
may be in the air without a visible dust cloud. If air 
monitoring for silica is not provided by your employer at 
your work site, you must wear appropriate respiratory 
protection when operating or maintaining this equipment. 
Consult your employer for proper respiratory protection. 

 

 

Содержание DM-2780

Страница 1: ...DM 2780 Safety Operators Manual ...

Страница 2: ...0 Safety Operators Manual 1800 FLOOREX PAGE 1 1800 356 673 Table of Contents Contents Table of Contents 1 Safety Instructions 2 Filter Cleaning 4 Operating Instructions 5 Electrical Safety 7 Problem Solving 9 ...

Страница 3: ...ion 5 For the operators safety and the safety of others always keep all guards and shrouds in place 6 This the Dust Extractor is intended for use with concrete dust 7 Do not lend or rent the Dust Extractor without the operating instructions for the Dust Extractor 8 Wear clothing suitable for the job and for the work place including safety shoes hard hat hearing protection non fogging vented safety...

Страница 4: ...an cause severe and permanent lung damage cancer and or other serious diseases Do not breathe the dust Do not rely on your sight or smell to determine if dust is in the air Silica may be in the air without a visible dust cloud If air monitoring for silica is not provided by your employer at your work site you must wear appropriate respiratory protection when operating or maintaining this equipment...

Страница 5: ...washing the pleats directly 3 Do not use compressed air to clean any filter as it can damage the media and allow dust to enter the motor 4 This Rotary Filter Cleaning System is very effective and takes only 10 20 seconds to deep clean the filter when the suction motors are turned off 5 The rotary filter cleaning is best performed when the motors are both stopped But can assist in the cleaning duri...

Страница 6: ...ed via the over center clamps provided before plugging the machine in to power 5 Connect the Dust Extractor to suitable power outlet This is normally 10A If you need to connect using extension cords please consult your supplier to confirm the best size conductor to use 6 Always move the Dust Extractor with the handles and not by pulling the hose Pulling the machine via the hose could make the mach...

Страница 7: ...y small like a hand grinder or even a Meteor 250 or a Satellite 480 and Satellite 650 11 Use both motors when using a wand and floor tool to clean the floor 12 The Head can be lowered using the handle lever and locked in place using the locks on either side 13 WARNING Breathable silica may be generated by use and maintenance of this the Dust Extractor Silica can cause severe and permanent lung dam...

Страница 8: ... Dust Extractor 6 Never connect or disconnect power cables with voltage present or while under load 7 Disconnect all power connections and observe lock out tag out procedures before attempting to carry out any maintenance or repair on any equipment 8 Avoid any contact with any rotating parts or driven parts 9 Never use equipment that has not been tested and tagged including cords 10 Before connect...

Страница 9: ...tractor to suitable power outlet This is 15A If you need to connect using extension cords please consult your supplier to confirm the best size conductor to use 11 The Dust Extractor can produce sound pressure levels greater than 85db The operator must wear approved safety ear protection ...

Страница 10: ...the head is correctly positioned on the main bowl and firmly against the seal If the bucket is not against the seal firmly air can come in and reduce the air flow and or suction The seal is missing at the Bottom Check the seal by eye and feel around the seal area for leaks and replace or re fit If the seals are not correctly fitted or missing the air flow and or suction will be greatly reduced The...

Страница 11: ... Manual 1800 FLOOREX PAGE 10 1800 356 673 Warranty Warranty is for a period of 12 months from original purchase date covering manufacturer s defects does not cover brushes on the motor which have an estimated life of 600 hours ...

Страница 12: ...0 356 673 Floorex Products Your complete supplier of all your concrete surface preparation needs Diamond grinders Dust extraction Shotblasters Screed mixers Diamond Tooling Floor Scrapers Coating application Web www floorex com au Email sales floorex com au ...

Отзывы: