DM-2780 Safety & Operators Manual
1800 FLOOREX
PAGE 6. 1800 356 673
9.
Switch the Filter cleaning switch on for 20-30 seconds prior
to operating if the filter is not clean.
a. This can be switched off after the 20-30
seconds but also can be left on during
vacuum operation.
b. Leaving the filter cleaning on during vacuum
operation is optional.
c. The filter cleaning does clean the filter a little
whilst the motors are on, but not as effective
as when the vacuum motors are off.
10. Switch the vacuum motors on using the toggle switches.
There is often no need to run all motors especially if the
tool it is connected to is fairly small like a hand grinder or
even a
Meteor™ 250 or a Satellite™ 480 and Satellite™
650.
11. Use both motors when using a wand and floor tool to clean
the floor.
12. The Head can be lowered using the handle lever and
locked in place using the locks on either side.
13. WARNING! Breathable silica may be generated by use
and maintenance of this the Dust Extractor. Silica can
cause severe and permanent lung damage, cancer, and or
other serious diseases. Do not breathe the dust. Do not rely
on your sight or smell to determine if dust is in the air. Silica
may be in the air without a visible dust cloud. If air
monitoring for silica is not provided by your employer at
your work site, you must wear appropriate respiratory
protection when operating or maintaining this equipment.
Consult your employer for proper respiratory protection.