5.
INITIAL START-UP & DISPLAY
The LT260 has two display modes; a measurement mode for displaying level and a programming
mode for application set-up.
Measure Mode:
In measurement mode, 4 LED’s are seen on the front panel of the LT260, shown below. A
Flashing “0” on the display is shown when it is in fault condition (Lost Echo).
LED
Condition
Function
Detect & Level
Flashing together
Indicates Normal Operation
Mode selected = Level
Detect & Distance Flashing together
Indicates Normal Operation
Mode selected = Distance
Detect & Space
Flashing together
Indicates Normal Operation
Mode selected = Space
Level or
Distance or
Space
Flashing alone
Indicates that LT260 is detecting an
echo but checking if the value is
correct.
None
All Off
Display indicates “E-Err”
Indicates that LT260 has gone into Fail
condition.
Reasons:
- There is no reflected echo received.
- Transducer and electronic part are
disconnected