Problem Solving
In this appendix, several problems are included that can occur when the Easybatch is going
to be installed or while it is in operation.
Flowmeter does not generate pulses
Check:
Signal selection SETUP 3.1.
Pulse amplitude (paragraph 4.6.1).
Flowmeter, wiring and connection of terminal connectors (paragraph 4.6.1).
Power supply of flowmeter (paragraph 4.4.2).
Flowmeter generates "too many pulses"
Check:
Settings for Total and Flowrate.
Type of signal selected with actual signal generated (paragraph 3.3.4),
Sensitivity of coil input.
Proper grounding of the Easybatch, avoid ground loops.
Use screened wire for flowmeter signals and connect screen to the ground input
terminal of the flowmeter input.
The password is unknown
If the PIN cannot be retrieved, there is only one possibility left: call your supplier.
ALARM ####
When the alarm flag starts to blink an internal alarm condition has occurred. Press the STOP
key several times to display the error code. The codes are:
0001
= display error
0002
= data-storage error
0004
= initialization error
When multiple alarms occur, the error code shown is the sum of the error codes as given
above.
E.g. 0005 is a combination of error code 0001 and 0004.
If the alarm occurs more often or stays active for a long time, please contact your supplier.