 Torque switches are factory set to actuator rated torque and should not be necessary 

to reset.  Call factory if you have special requirement.  Torque switches set with 

special tools to protect the actuator.  If re-set without factory consultation warranty 

may be voided. 

     6) Adaptation mounting for  Actuator and valve  

        6.1  Drive Bushing 

           1) Removal  

           

An internal actuator drive bushing is assembled on the bottom of the actuator with 4      

          retaining screws.  Socket hex-key wrench is required for their removal.    

           

2)  Machining 

            The Drive bushing is machined to adapt to valve shaft ( or mounting coupler if         

              actuator is not direct mounted to the valve.)  If key/keyway adaptation is used the 

             directionof keyway should align with one of the drive busing screws. 

 

 

     

 

 

 

   

 6.2  Reassembling  the drive bushing 

           1) Check 

the relative position of valve and actuator (Open-Closed). 

                If not rotate the actuator to same position as valve. 

           2)  Line UP actuator 

key way or other shaft configuration ( Square, etc.)  with valve 

                 Shaft or coupler  Key Way, etc. ** Actuator can mount in one of 4 quadrants as determined by  

                the drive busing installed position. 

            

3)  Insert 

the drive bushing back into the actuator with the 4 retaining screws. 

 

 

Trouble shooting 

Содержание FCEL

Страница 1: ... once electric power is energized If in manual mode when electric power is re energized actuator will automatically declutch and operate 2 2 Valve Position Indication Actuator Top mounted Visual position indication shows OPEN and CLOSED valve position 3 Wiring Connections 3 1 Top Housing Cover Removal Remove the 4 Socket head Housing Capscrews with a hex key wrench Lift housing cover from actuator...

Страница 2: ...n screw 4 2 Setting the Open Limit Switch Upper Cam and Upper Switch 1 Pull the declutch lever and turn Handwheel counter clockwise to move the valve to the fully Opened position 2 Using a hex key wrench loosen the upper cam screw Opened LS 3 Adjust the cam to trip the upper cam switch LS then tighten screw 4 3 Mechanical Travel Limit Stops TLS 1 Closed Travel Limit Stop is on Left and Open Travel...

Страница 3: ... removal 2 Machining The Drive bushing is machined to adapt to valve shaft or mounting coupler if actuator is not direct mounted to the valve If key keyway adaptation is used the directionof keyway should align with one of the drive busing screws 6 2 Reassembling the drive bushing 1 Check the relative position of valve and actuator Open Closed If not rotate the actuator to same position as valve 2...

Страница 4: ...rol panel replace defective parts Control Panel 1st If NO Control Panel problem Check Actuator Then Actuator 3 Check the Actuator Motor and replace if necessary 4 Torq Switch Tripping turn main power off and follow Mechanical Trouble Shooting procedure 5 Check for faulty Limit switch with circuit check adjust or replace 6 All other electrical problems can be resolved by parts Replacement FCEL Actu...

Отзывы: