SITE PREPARATON FOR INSTALLATION:
We recommend that the chosen installation area is flat – clear the area of bricks, tiles glass, and anything else that maybe present before levelling out.
Each RainPac
TM
bladder has its own height clearance requirements based on the width of the bladder. Details of the required clearances are as follows:
(made to order tanks will have the height clearance written on the label of the bladder box)
BLADDERS WIDTH (METRES/MM)
REQUIRED HEIGHT CLEARANCE ( MINIMUM)
1 metre – 1000mm
400mm
1.3 metres – 1300mm
500mm
1.6 metres – 1600mm
650mm
2 metres – 2000mm
715mm
2.3 metres – 2300mm
715mm
2.6 metres – 2600mm
715mm
Installation of the overflow system above these height restrictions will mean the RainPac
TM
will overfill, and this will void the warranty. If you do not have
enough height as per the guide above, the overflow can be dropped to the height you have available without voiding the warranty.
RainPac
TM
must be installed on flat ground.
Some general rules to follow when selecting the site:
1.
Make sure the corresponding bladder and clearance requirement listed above suits the selected area;
2.
The area should be relatively close to the downpipe/s from where the RainPac
TM
will fill. Additionally, as all fittings are situated at one end, this end
should be the closest to the downpipe/s(where possible); and,
3.
The chosen site should be dedicated to the RainPac
TM
with nothing else being stored near the bladders that could damage them.