4. IF YOU WISH TO ADD THE COOLER/HUMIDIFIER FUNC-

TION, PRESS THE COOLER/HUMIDIFIER BUTTON. 

NOTE: THE ECO AIR COOLER IS EQUIPPED WITH A FLOAT SWITCH. IF THERE 

IS NOT ENOUGH WATER IN THE WATER TANK, THE UNIT WILL EMIT A WARN-

ING SOUND AND THE COOLER/HUMIDIFIER FUNCTION WILL AUTOMATICALLY 

SHUT OFF. 

          TROUBLESHOOTING TIP

If the Cooler/Humidifier function automatically shuts off even though there 

is enough water in the tank, the float switch that protects the water pump 

is stuck. When the float switch is stuck, the unit acts as if there is no water in 

the tank. In order to dislodge the float switch, please drain the unit of wa-

ter and ensure that it is dry. Grab the handles on the sides of the unit and 

shake the unit from side to side and up and down vigorously. This will reset 

the float switch and the Cooler/Humidifier function will work properly.

5. NOW THAT THE UNIT IS ON, THE TIMER, SWING, MODE, 

OR -ION FUNCTIONS CAN NOW BE ACTIVATED AND SET 

BY SELECTING THEIR BUTTONS.

6. ANYTIME WHEN YOU WANT TO STOP THE UNIT, PRESS 

THE OFF BUTTON.

7. REMOTE CONTROL

A. The unit can also be controlled directly with the remote control. Open the 

battery cover on the bottom of the remote control and install a 3V CR2032 bat-

tery (see Figure 3).

B. There are 7 keys on the remote control, they function the same as the button 

controls on the control panel.

When using remote control, it should be aimed at the Control Panel of the unit. 

The remote is effective up to a distance of 6 meters.

*

Содержание DF169

Страница 1: ...ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER floater imports DF169 USER S MANUAL...

Страница 2: ...porates Evaporation is a endothermic process it absorbs heat the energy used in evaporating the water drops the temperature of the air flowing through the cool ing pad As a result the airflow from the...

Страница 3: ...COOLER Place the rear of the ECO AIR COOL ER in front of an opened door or window Evaporative coolers are most efficient when they have a constant supply of fresh air The colder the water is in the wa...

Страница 4: ...TION OF COMPONENTS 1 Indicator Panel 7 Water Tank 2 Wind Outlet 8 Water Tank Lock 3 Power Cord 9 Ice Packs 4 Water Level Indicator 10 Remote Control 5 Casters 11 Drain Plug 6 Dust Filter CONTROL PANEL...

Страница 5: ...re quired amount of water in the water tank If the Cooler Humidifier button is pressed and there is not enough water in the tank or if the water level falls below the minimum a warning sound will emi...

Страница 6: ...or HIGH as set Natural Mode The fan operates in a random cycle of a combination of OFF LOW MEDIUM and HIGH to simulate a natural breeze By pressing each of the three wind speeds a unique natural wind...

Страница 7: ...ged particles or ions are cir culated from the cooler they attract dirty particles such as dander dust pollen and cigarette smoke until they become so heavy that they simply fall to the ground removin...

Страница 8: ...k of the unit and pull the water tank out as far as possible Pour cold and clean water into the water tank Figure 1 Be mindful of the water level indicator when adding water to control the quantity Fi...

Страница 9: ...e that it is dry Grab the handles on the sides of the unit and shake the unit from side to side and up and down vigorously This will reset the float switch and the Cooler Humidifier function will work...

Страница 10: ...r two months COOLING PAD Disconnect power Remove the Dust Filter and then push inwards on the tabs at the top of the Cooling Pad Frame to loosen the Cooling Pad Frame Then pull it outwards to remove T...

Страница 11: ...g repairing moving or adding water If the machine tips over with water in it disconnect power plug immedi ately Remove drain plug at the back of the water tank to remove water Let machine dry out for...

Страница 12: ...should last 5 years of seasonal use Should you re quire a replacement please contact your point of purchase To replace the Cool ing Pad remove the Cooling Pad Frame from the unit Remove the old Cooli...