background image

CAUTION

Do not use excessive force when turning the control dial, damage to the cam-
era probe can result. Do not attempt to force the flexible neck past its maxi-
mum angle. Stop turning the control dial when the maximum angle is reached.

Image and Video Capture Button

Short press the Image and Video Capture button (6)

to capture a

still image. Long press to start or stop video recording. Images and
videos are stored on the VS80 micro SD card.

The VS80 user manual provides detailed information regarding me-
dia management. Obtain the user manual from the FLIR support
website (see Support section below).

Brightness Control Buttons

Use the brightness controls

(7, 8) to increase and decrease

the brightness of the camera images.

Control Button Lock Switch

Use the locking switch (9) to disable the three control buttons (6, 7,
8). This is useful to avoid inadvertent activation of the buttons.

Safety

Please read and understand all safety cautions before use.

CAUTION

Do not insert the probe into flammable liquid or gas.

The probe contains small circuitry that controls the optics and electronics of
the camera. To ensure reliability, do not bend the probe more than 90°, and,
when storing, always coil the probe in a large arc.

This product is designed for industrial use only. It is not intended for use in hu-
man or other biological inspection.

#NAS100102; r. AB/83682/84877; en-US

3

Содержание VS80A2-45-1RM

Страница 1: ...User Manual Two Way Articulating Camera Probe Model VS80A2 45 1RM...

Страница 2: ...l transla tions of this user manual on the support site https support flir com Description 1 Probe 2 Articulating neck 3 Camera head 4 Articulation control dial 5 Slider to lock articulation 6 Image a...

Страница 3: ...l 4 clockwise to bend the probe neck to the right turn the dial counter clockwise to bend the neck to the left as shown in the image below The articulation range is 180 maximum do not attempt to force...

Страница 4: ...pport section below Brightness Control Buttons Use the brightness controls 7 8 to increase and decrease the brightness of the camera images Control Button Lock Switch Use the locking switch 9 to disab...

Страница 5: ...the probe is particularly sensitive to excessive force Never bend the neck by hand use only the control dial Keep the insert neck as straight as possible while in use Never insert or bend the neck by...

Страница 6: ...an occur Before inspecting a vehicle shut off the engine Allow the metal and liquids in the vehicle to cool before inspection CAUTION To clean the probe wipe with a soft cloth dampened with a mild det...

Страница 7: ...CPC hy draulic oil 46AWS Ingress protection Probe tip and body IP 67 IEC 60529 Protected from submersion in water up to 1 meter 3 3 ft for 30 minutes maximum In use rain splashes and accidental submer...

Страница 8: ...NAS100102 r AB 83682 84877 en US 7...