5.5.2.4 — Area
]
ThermaCAM™ PM575/595
Operator’s Manual
32
button to resume the normal function of the joystick, i.e. focus/zoom. To move the
crosshair next time, it is necessary to confirm
Spot
(or
Spot 1, 2 or 3
) in the
Anal-
ysis
menu.
In
Maximum
(or
Minimum
) mode four corners of a box are displayed on the screen
when the spotmeter function is activated. The size of the box can be controlled by
using the joystick. When the desired box size has been set press the
↵
button to
resume the normal function of the joystick. To change the size of the box next time,
it is necessary to confirm
Spot
again (or
Spot 1
if
Maximum
or
Minimum
is
selected in the
Setup – Analysis
dialog box;
Setup
→
Analysis
).
The crosshair will now continuously move to the part of the image within the box
where it hits the maximum (or minimum) temperature.
5.5.2.4
Area
The area function measures either the maximum, minimum or average temperature
within a rectangular or circular area around the centre of the image. The result is
indicated by the
Amin
,
Amax
or
Aavg
text in the result table. To resize the rectan-
gle, confirm
Area
in the
Analysis
menu. The size of the area can then be controlled
by the movement of the joystick in the following way while the text
Joystick: Area
size C: Remove
is shown at the bottom of the screen. To change the size of the
area next time, it is necessary to confirm
Area
in the
Analysis
menu again.
•
Joystick Up:
Increases the rectangle height or circle radius.
•
Joystick Down:
Decreases the rectangle height or circle radius.
•
Joystick Left:
Decreases the rectangle width or circle radius.
•
Joystick Right:
Increases the rectangle width or circle radius.
Once the required area size has been set, press the
↵
button to resume the nor-
mal function of the joystick, i.e. focus/zoom.
The
Area
type (i.e.
Box
or
Circle
) and the
Area
function (i.e.
Amin
,
Amax
or
Aavg
)
are selected in the
Setup
→
Analysis
→
Area type
and
Setup
→
Analysis
→
Area
function
menu (see “Setup menu” on page 35).
5.5.2.5
Profile
The profile function shows a horizontal or vertical temperature graph, depending
on the
Setup
→
Analysis
→
Profile
setting (see “Setup menu” on page 35), marked
by the profile line. The temperature of the cursor is indicated by the
Cur
text in the
result table. To move the cursor and the line along which the measuring takes
place, confirm
Profile
in the
Analysis
menu. The position of the cursor can then be
controlled by the movement of the joystick while the text
Joystick: Prof pos C:
Remove
is shown in the bottom left-hand corner of the viewfinder. Once the