FLIR TG54 Скачать руководство пользователя страница 28

 

FLIR

 

TG54_TG56

 

User

 

Manual

                                         

28

             

Document

 

Identifier:

 

TG54_TG56

en

US_AA

 

responsible

 

for

 

complying

 

with

 

all

 

RMA

 

instructions

 

provided

 

by

 

FLIR

 

including

 

but

 

not

 

limited

 

to

 

adequately

 

packaging

 

the

 

Product

 

for

 

shipment

 

to

 

FLIR

 

and

 

for

 

all

 

packaging

 

and

 

shipping

 

costs.

 

FLIR

 

will

 

pay

 

for

 

returning

 

to

 

Purchaser

 

any

 

Product

 

that

 

FLIR

 

repairs

 

or

 

replaces

 

under

 

warranty.

  

FLIR

 

reserves

 

the

 

right

 

to

 

determine,

 

in

 

its

 

sole

 

discretion,

 

whether

 

a

 

returned

 

Product

 

is

 

covered

 

under

 

Warranty.

 

If

 

FLIR

 

determines

 

that

 

any

 

returned

 

Product

 

is

 

not

 

covered

 

under

 

Warranty

 

or

 

is

 

otherwise

 

excluded

 

from

 

Warranty

 

coverage,

 

FLIR

 

may

 

charge

 

Purchaser

 

a

 

reasonable

 

handling

 

fee

 

and

 

return

 

the

 

Product

 

to

 

Purchaser,

 

at

 

Purchaser’s

 

expense,

 

or

 

offer

 

Purchaser

 

the

 

option

 

of

 

handling

 

the

 

Product

 

as

 

a

 

non

warranty

 

return.

  

7.

 

NON

WARRANTY

 

RETURN.

 

Purchaser

 

may

 

request

 

that

 

FLIR

 

evaluate

 

and

 

service

 

or

 

repair

 

a

 

Product

 

not

 

covered

 

under

 

warranty,

 

which

 

FLIR

 

may

 

agree

 

to

 

do

 

in

 

its

 

sole

 

discretion.

 

Before

 

Purchaser

 

returns

 

a

 

Product

 

for

 

non

warranty

 

evaluation

 

and

 

repair,

 

Purchaser

 

must

 

contact

 

FLIR

 

by

 

visiting

 

http://www.flir.com

 

to

 

request

 

an

 

evaluation

 

and

 

obtain

 

an

 

RMA.

 

Purchaser

 

is

 

solely

 

responsible

 

for

 

complying

 

with

 

all

 

RMA

 

instructions

 

provided

 

by

 

FLIR

 

including

 

but

 

not

 

limited

 

to

 

adequately

 

packaging

 

the

 

Product

 

for

 

shipment

 

to

 

FLIR

 

and

 

for

 

all

 

packaging

 

and

 

shipping

 

costs.

 

Upon

 

receipt

 

of

 

an

 

authorized

 

non

warranty

 

return,

 

FLIR

 

will

 

evaluate

 

the

 

Product

 

and

 

contact

 

Purchaser

 

regarding

 

the

 

feasibility

 

of

 

and

 

the

 

costs

 

and

 

fees

 

associated

 

with

 

Purchaser’s

 

request.

 

Purchaser

 

shall

 

be

 

responsible

 

for

 

the

 

reasonable

 

cost

 

of

 

FLIR’s

 

evaluation,

 

for

 

the

 

cost

 

of

 

any

 

repairs

 

or

 

services

 

authorized

 

by

 

Purchaser,

 

and

 

for

 

the

 

cost

 

of

 

repackaging

 

and

 

returning

 

the

 

Product

 

to

 

Purchaser.

 

Any

 

non

warranty

 

repair

 

of

 

a

 

Product

 

is

 

warranted

 

for

 

one

 

hundred

 

eighty

 

days

 

(180)

 

days

 

from

 

the

 

date

 

of

 

return

 

shipment

 

by

 

FLIR

 

to

 

be

 

free

 

from

 

defects

 

in

 

materials

 

and

 

workmanship

 

only,

 

subject

 

to

 

all

 

of

 

the

 

limitations,

 

exclusions

 

and

 

disclaimers

 

in

 

this

 

document.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TG54

Страница 1: ...USER MANUAL FLIR IR Spot Thermometers TG54 IR Spot Thermometer TG56 IR Spot Thermometer with Thermocouple...

Страница 2: ...6 4 DESCRIPTIONS 7 4 1 Rear Description 7 4 2 Front Description 7 4 3 Top Description 7 4 4 Main Display Description 8 4 5 Display Icon Descriptions 9 4 6 Control Buttons and Trigger Descriptions 10 5...

Страница 3: ...e Help Screen 20 6 2 8 Viewing the Info Screen 20 7 MAINTENANCE 21 7 1 Battery Replacement 21 7 2 Calibration 21 7 3 Cleaning 21 8 SPECIFICATIONS 22 8 1 General Specifications 22 8 2 Environmental Spe...

Страница 4: ...nced herein are used for identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactur...

Страница 5: ...rstand all of the information provided in this User Guide and other included documentation before use o Use caution when the Class 1 Laser pointer is on Do not point the beam toward anyone s eye or al...

Страница 6: ...mable IR Spot Thermometer Quick boot time one second approximately Bright easy to read graphical color display Laser Pointer for targeting accuracy 30 1 TG56 and 24 1 TG54 Distance to Spot ratio Easy...

Страница 7: ...light button 6 Battery compartment internal 7 Twist off end cap to access batteries 4 2 Front Description 1 Laser pointer lens 2 Work lights 3 IR Thermometer lens 4 Measurement trigger 5 Lanyard atta...

Страница 8: ...reading digits 13 Second most recent reading digits 14 Third most recent reading digits 4 4 2 Main Display Screen TG56 1 Laser pointer active 2 Trigger pressed scan mode 3 Mode icon area thermocouple...

Страница 9: ...reading mode High Alarm Reading 3 in three reading mode Low Alarm Thermocouple attached TG56 Work light active Delta mode MAX minus MIN Full battery power MIN reading Low batter power MAX reading Emis...

Страница 10: ...ress to access the Programming menu short press to confirm open a menu parameter and toggle select a menu option UP DOWN ARROW NAVIGATION BUTTONS Scroll the selections in the Programming menu Steps th...

Страница 11: ...es has a programmable APO Auto Power OFF feature where it automatically shuts off after the trigger is released after 5 10 or 20 seconds Please refer to Section 6 Programming Menu for instructions on...

Страница 12: ...24 1 From a distance of 24 the TG54 measures the average temperature of a spot 1 in diameter From a distance of 48 the spot diameter is 2 and from a distance of 72 the spot diameter is 3 The temperatu...

Страница 13: ...ng Menu The meter will alert the user when an alarm threshold has been triggered by changing the color of the temperature reading digits red for high alarm trip and blue for low alarm trip If the alar...

Страница 14: ...ar the middle of the top row of icons The average reading is shown next to the average icon and the MAX minus MIN reading is shown next to the second delta symbol located on the lower half of the disp...

Страница 15: ...of the object under test with the IR Thermometer 2 Measure the same surface with the Type K thermocouple thermometer 3 Note the difference delta between the two readings 4 Now adjust the Emissivity in...

Страница 16: ...will appear on the upper left hand corner 3 Use the arrow buttons to scroll through the menu items and pages not all menu items can be displayed on one page use the arrow buttons to scroll through pa...

Страница 17: ...TG56 Emissivity Select a preset 0 95 0 85 0 75 0 65 or set a custom emissivity value at the custom emissivity icon Alarm Modes Program OFF Low High or Low High Alarms Laser Pointer ON OFF use MENU bu...

Страница 18: ...rials and their respective Emissivity factors 1 Press and hold Menu to access the Programming menu and use the arrows to scroll to the emissivity icon 2 Press Menu to open the item 3 EMISSIVITY PRESET...

Страница 19: ...the desired Low alarm threshold c Press Menu to confirm and press to return to the Programming menu 5 Follow the steps above to program the other alarm modes Note that the High alarm threshold cannot...

Страница 20: ...nother menu item or press to return to the normal operating mode 6 2 7 Viewing the Help Screen From the Help screen in the Programming menu the user can view FLIR contact information and other useful...

Страница 21: ...polarity Slide the battery tray back into the handle in the original orientation Screw the cap back onto the handle 7 2 Calibration The meter is calibrated at the factory prior to shipment If calibrat...

Страница 22: ...10 and 20 seconds Alarms Color coded High Low and High Low combination alarms Certifications CE FDA Laser Warranty 5 years Accessories Includes Lanyard Type K thermocouple TG56 User Guide Dimensions...

Страница 23: ...ngle 0 04 o IR Temperature Response Time 150ms Temperature Scanning Continuous Emissivity 4 presets plus a custom setting 0 10 0 99 8 4 Laser Specifications Laser type Single Class 1 Laser red visible...

Страница 24: ...98 Cement 0 96 Leather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Soil 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85...

Страница 25: ...it does emit infrared radiation which we feel as heat The warmer the object the more infrared radiation it emits IR Thermometers measure an object s surface temperature The thermometer s optics sense...

Страница 26: ...en US_AA 10 Customer Support Main Website http www flir com test Technical Support Website http support flir com Technical support Email TMSupport flir com Service Repair Support Email Repair flir com...

Страница 27: ...nform to FLIR s published product specifications and be free from defects in materials and workmanship during the applicable Warranty Period PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY A...

Страница 28: ...y which FLIR may agree to do in its sole discretion Before Purchaser returns a Product for non warranty evaluation and repair Purchaser must contact FLIR by visiting http www flir com to request an ev...

Страница 29: ...70 USA Telephone 1 503 498 3547 Customer Support Technical Support Website http support flir com Technical Support Email TMSupport flir com Service and Repair Email Repair flir com Customer Support Te...

Отзывы: