FLIR
LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
15
correction (SBNUC) algorithm which relies on motion within the scene to isolate fixed pattern noise (FPN) from
image content.
2.11.4
AGC
The AGC algorithm for converting the full-resolution (14-bit) thermal image into a contrast-enhanced image
suitable for display is a histogram-based non-linear mapping function
2.11.5
Colorize
The colorize block takes the contrast-enhanced thermal image as input and generates a 24-bit RGB color output.
See
2.12
Master Clock
In Lepton the master clock (MASTER_CLOCK) frequency is 25 MHz.
3
Operating States and Modes
Lepton provides several operating states and modes, more completely defined in the sections that follow:
•
•
•
•
•
•
•
•
3.1
Power States
Lepton currently provides five power states. As depicted in the state diagram shown in
, most of the
transitions among the power states are the result of explicit action from the host. The automatic transition to and
from the over-temperature (Overtemp) state is an exception.