![FLIR identiFINDER R200 Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/flir/identifinder-r200/identifinder-r200_manual_2306028076.webp)
Chapter 5 Alarms
This chapter details configuration and instructions for the setting and use of the alarms on the FLIR identiFINDER
R200.
5.1 Alarms for Radiation Levels
Navigate the following menus to access the Gamma
alarms for Dose Rate, Dose Threshold, and the
Sigma (standard deviation) alarms
Levels may be set for Warnings and Alarms for both
Dose Rate Threshold and Dose Threshold, and an
alarm may also be set for the Sigma Threshold
Alarm .
The thresholds are numeric values consistent with
the Dose Rate, Dose and Sigma Thresholds.
They may be set by scrolling up or down the dis-
played list of numeric values (micro rem per hour for
Dose Rate and micro rem for Dose).
The Sigma alarm may be set in increments of one
tenth for standard deviation between 1.0 and 9.9.
As with many other functions in the FLIR
identiFINDER R200 menu system, selecting a value
from the scroll list requires that the selection be con-
firmed by clicking the circled checkmark
com-
mand button.
Reminder
:
Dose
Rate
is a function of dose over a given
range of time (6 μrem/hr).
Dose
is a total, or cumulative dose (100
μrem), and continues to "stack" until it is reset.
Access the accumulated total and the accu-
mulation of time since last reset by navigating
the menus - Data/Counters/Dose Info menu.
Reset the value to zero and begin collecting a
new tally by selecting the recycle button
in the taskbar.
An analogy would be the speedometer and
odometer in an automobile. The speedometer
is an indicator of the car's rate of speed in real
time (6 mph), and the odometer is a measure
of total distance traveled say on a trip, or over
several excursions (400 km total distance
traveled since the odometer was last set to
zero).
The Dose is similar to the trip meter in a car
(an odometeris a "counter" of total miles
logged), and the speedometer in the vehicle is
5 - 69
R200 3/10/2017
__
1:38 PM
Содержание identiFINDER R200
Страница 8: ...Welcome 1 1 R200 3 10 2017__1 38 PM ...
Страница 112: ...B2 Firmware Installation B2 Firmware Installation identiFINDER R200 ENGLISH en 3 10 2017 1 38 PM 9 105 ...
Страница 113: ...B2 Firmware Installation 9 106 identiFINDER R200 ENGLISH en 3 10 2017 1 38 PM ...
Страница 114: ...B2 Firmware Installation identiFINDER R200 ENGLISH en 3 10 2017 1 38 PM 9 107 ...
Страница 115: ...B2 Firmware Installation 9 108 identiFINDER R200 ENGLISH en 3 10 2017 1 38 PM ...
Страница 130: ......