background image

 
FlashSight™ User’s Guide 

 

 

Copyright © 2006, FLIR Systems, Inc. 431-0002-09-10 Version 100 

 

3 Quick-Start 

Information 

The following instructions will get you started with basic operation of the 
FlashSight. 
 

1.  Insert 4 AA batteries inside the battery case as shown in Figure 2, 

being careful to align the positive and negative battery terminals as 
depicted in the embossed diagram on the case. 

2.  Insert the battery case into the FlashSight battery compartment as 

shown in Figure 3. The compartment is keyed to prevent the case from 
being inserted upside-down. 

Note 

The FlashSight battery compartment is designed to accept the included battery case 
only. Do not insert batteries directly into the compartment without using the case. 

3.  Press the on/off button on the left side of the FlashSight assembly as 

shown in Figure 4. You should hear one or more audible “clicks” from 
the sight. This is the internal shutter, which is used to automatically 
improve the uniformity of the detector array at periodic intervals. Open 
the lens cap by rotating it upward, as shown in Figure 5. 

4.  Hold the eyecup to your eye, pressing slightly against your face to 

open the eyecup flaps. Adjust the eyepiece focus by rotating the 
eyepiece, as shown in Figure 6. If necessary, also adjust the focus of 
the lens assembly as shown in Figure 7. 

Note 

The eyepiece focus adjustment optimizes the focus of the eyepiece for your vision 
and should only be required once. The lens focus adjustment optimizes the focus of 
the infrared imager, and can be varied during operation depending upon whether you 
are imaging distant or nearby targets. Begin by adjusting the eyepiece focus while 
looking at the crosshair on the display. Then adjust the lens focus while looking at 
the image of the object you are trying to see. If the crosshair is not displayed when 
you first power the unit, see Section 4.4 for directions on how to display it. 

5.  To turn the unit off, press and hold the on/off button for two seconds. 

The display will go black, indicating that the system is powered down. 

You have now completed the basic steps for using the imager. However, it is 
recommended that you read the rest of this User’s Manual to learn how to 
adjust the image according to your preferences, how to override automatic 
shutter operation, how to capture and download images, and how to maintain 
your FlashSight system. 

Содержание FlashSight

Страница 1: ...Copyright 2006 FLIR Systems Inc 431 0002 09 10 FlashSight User s Guide INDIGO OPERATIONS...

Страница 2: ...ut permission and shall not be duplicated used or disclosed in whole or in part except to the extent provided in any contract of which this document is made a part This restriction does not limit the...

Страница 3: ...ormation 5 4 FlashSight User Controls 7 4 1 On Off Button 7 4 2 Shutter Button 8 4 3 Image Capture Button 9 4 4 Menu Control 10 4 5 Eyepiece Focus 12 4 6 Lens Focus 12 5 FlashSight Image Download 12 6...

Страница 4: ...re range 40 o C to 55 o C Not all AA batteries are specified over this same temperature span Check the manufacturer s specifications of your selected battery to verify the valid temperature range For...

Страница 5: ...jective lens When the lens cap is not in place avoid pointing the sight directly at extremely high intensity radiation sources such as the sun lasers arc welders etc This warning applies whether or no...

Страница 6: ...as a handheld device The heart of the FlashSight assembly is Indigo Systems Micron Omega core the world s smallest lightest lowest powered infrared imager Two lens options are available 30 mm 13 9 x 9...

Страница 7: ...FlashSight User s Guide Copyright 2006 FLIR Systems Inc 431 0002 09 10 Version 100 4 Figure 1 FlashSight Deluxe Kit...

Страница 8: ...eyecup to your eye pressing slightly against your face to open the eyecup flaps Adjust the eyepiece focus by rotating the eyepiece as shown in Figure 6 If necessary also adjust the focus of the lens a...

Страница 9: ...09 10 Version 100 6 Figure 2 Installing batteries in the battery case Figure 3 Installing the battery case into FlashSight Figure 4 Turning on FlashSight Figure 5 Opening the lens cap Figure 6 Adjusti...

Страница 10: ...ure 8 FlashSight User Controls 4 1 On Off Button The on off button is located on the left side of the FlashSight assembly To turn the system on simply press the button then release To prevent inadvert...

Страница 11: ...l the shutter operation is completed While it is recommended to leave FlashSight in its automatic shutter mode whenever possible there are certain circumstances that call for a disabled shutter One of...

Страница 12: ...hen the gauge reaches 100 a memory full icon will appear when you attempt to capture another frame which indicates no more images can be stored without first deleting the full contents of memory The m...

Страница 13: ...is a push turn device i e it can be rotated like a knob and also pushed like a button Pressing the button will cause an on screen menu as shown in Figure 12 to be displayed Each row of the menu allow...

Страница 14: ...rast to be adjusted Note The cursor will skip over the third row when the sight is in automatic video optimization mode In this mode brightness and contrast settings are updated automatically To adjus...

Страница 15: ...on the focus adjustment of the lens The seal on the eyepiece can be tight so it may be necessary to squeeze the base firmly to adjust focus 4 6 Lens Focus The camera lens is focused by rotating the le...

Страница 16: ...mm 8 3 x 6 3 Eyepiece eye relief 25 mm 1 inch Temporal NEdT Configuration Sensitivity NEdT 30 mm f 1 6 85 mK 50 mm f 2 0 85 mK Turn on time Time Degrees 4 seconds above 10 C 14 F 30 seconds at 32 C 2...

Страница 17: ...e subject to change without notice See the FlashSight Product Specification ISC doc 431 0001 01 09 for detailed requirements 7 FlashSight Interfaces RS170A NTSC compatible output 75 ohm load impedance...

Страница 18: ...tissue onto the lens surface and then drag the tissue across the lens surface Repeat several times with different pieces of tissue 2 Repeat the same step using IPA instead of water Drag the final piec...

Страница 19: ...the objective of finding a single material that would give the desired reduction in brightness as well as the maximum reduction in heat He began the experiment by actually repeating Newton s prism ex...

Страница 20: ...ably be doomed to the use of reflective elements exclusively i e plane and curved mirrors Fortunately this proved to be true only until 1830 when the Italian investigator Melloni made his great discov...

Страница 21: ...y patents were issued for devices to detect personnel artillery aircraft ships and even icebergs The first operating systems in the modern sense began to be developed during the 1914 18 war when both...

Страница 22: ...military infrared research programs into the possibilities of developing passive no search beam systems around the extremely sensitive photon detector During this period military secrecy regulations c...

Отзывы: