CM-6308-P1-I FW v.20190226 Release Notes
April 2, 2019
By default, the camera is set to
auto detect the connected power source’s power level. If the camera
detects insufficient levels and the power source does not support enhanced network negotiations
(LLDP), the camera may reboot up to 5 times in 20 minutes and enter a limited features state, as above.
The user has an option on the Basic Configuration page to manually set the camera on PoE+. This may
be useful in cases where the camera is connected to a valid power source, such as UPoE, but initializes
on the limited features mode. This is because the camera is only looking for PoE+ or 24VAC power
sources, so it needs to be manually set on ‘PoE+’.
Note that if the camera changes its power level, for example, by turning on IR LEDs or heater, it would
consume additional power, and if that power is not available, it may change its power state to the limited
features state or reboot several times, as described above.
Figure 5
– Power Type Control