When an alarm is triggered, the camera can perform one or more tasks, e.g. save an im-
age or video sequence to camera memory, or send the image/video by e-mail to prede-
fined recipients or to an FTP site. The camera can also further trigger a variety of
external devices, using the digital output.
All active alarms are listed in the
Active alarms
section. A triggered alarm turns red in the
Active alarms
section. Also, the label of the measurement tool in the image turns red.
10.4.2.1
Setting an alarm based on a measurement result
To configure an alarm based on the measurement result from a spot, box, or delta meas-
urement tool, follow this procedure:
1. In the
Active Measurements
section, click the plus sign under
Add alarm
next to the
measurement result to be used for the alarm. The
Add alarm
dialog box appears.
2. In the
Alarm label
section, type an
Alarm name
.
3. In the
Trigger
section, select the
Condition
and temperatures that will trigger this
alarm:
Below
Triggers an alarm when the temperature is below the specified
Thresh-
old
value. Also type a
Hysteresis
value.
Above
Triggers an alarm when the temperature is above the specified
Thresh-
old
value. Also type a
Hysteresis
value.
Interval
Triggers an alarm when the temperature is within the specified
Min val-
ue
and
Max value
.
Hysteresis
is the interval within which the temperature value is allowed to vary without
causing a change in the trigger. If the threshold is set above 30.0°C and the hystere-
sis is set at 2.0°C, the trigger goes high when the temperature rises above 30.0°C
and stays high until the temperature drops below 28.0°C. In contrast, if the threshold
is set below 30.0°C, and the same hysteresis value is kept, the trigger goes high if
the temperature drops below 30.0°C and stays high until the temperature rises above
32.0°C.
4. In the
Threshold time
box, type the amount of time that has to pass before an alarm
is triggered. This can be used to avoid false alarms.
5. In the
Action
section, select which actions the camera will perform when an alarm is
triggered:
Digital OUT
Outputs a digital pulse. Also, type a pulse length (in millisec-
onds) in the
Pulse time
box.
Automatically sends the captured
Image
,
Result
, or
Video
to the
recipients defined in
Settings
>
Alarm recipients
. For more infor-
mation, see section 10.6.2
Send to FTP
Automatically sends the captured
Image
or
Video
to the FTP
site defined in
Settings
>
Alarm recipients
. For more information,
see section 10.6.2
, page 33.
Save to camera
Automatically saves the captured
Image
or
Video
to the memo-
ry of the camera.
During alarm
Temporarily disables the periodic calibration while the image/
video is being captured.
The image/video can later be viewed and managed under the
Library
tab:
• the captured image frame that triggered the alarm,
• the 5 second video sequence when the alarm was triggered.
6. When completed, click
Set alarm
. The alarm is now listed under
Active alarms
.
#T810579; r. AB/78918/78918; en-US
21
Содержание A50 Series
Страница 1: ...User s manual FLIR A50 A70 series nbn Austria GmbH...
Страница 42: ...Pin configurations 11 Figure 11 2 Ethernet cable M12 to RJ45 T810579 r AB 78918 78918 en US 38...
Страница 47: ...A series connection board 12 12 1 Connection examples See next page T810579 r AB 78918 78918 en US 43...
Страница 54: ...Mechanical drawings 14 See next page T810579 r AB 78918 78918 en US 50...
Страница 56: ...EU Declaration of conformity 15 See next page T810579 r AB 78918 78918 en US 52...
Страница 66: ...Notes T810579 r AB 78918 78918 en US 62...
Страница 67: ...Notes T810579 r AB 78918 78918 en US 63...