Installation
7
Figure 7.7
Dip switch locations in the FLIR A3xx pt series camera.
Pelco Address: This is the address of the system when configured as a Pelco device. The
available range of values is from decimal 0 to 255.
Table 7.1
Dip switch address/ID settings—SW102
ID
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
...
...
...
...
...
...
...
...
...
255
ON
ON
ON
ON
ON
ON
ON
ON
Other serial communication parameters: The tables below defines the switch locations, bit
numbering, and on/off settings.
Table 7.2
Dip switch address/ID settings—SW103
Settings
Descrip-
tion
Baud rate
: This is the baud rate of the system user serial
port. The available values are 2400, 4800, 9600, 19200
kbaud.
Bit 1
Bit 2
OFF
OFF
2400
ON
OFF
4800
OFF
ON
9600
ON
ON
19200
Camera control protocol
: This is the communication pro-
tocol selected for the system when operating over the seri-
al port. The available protocols are Pelco-D and Bosch.
Bit 3
Bit 4
OFF
OFF
Pelco-D
ON
OFF
N/A
OFF
ON
Bosch
ON
ON
N/A
Serial communication protocol
: This determines the
electrical interface selected for the user serial port. The
available settings are RS-422 and RS-232.
Bit 5
Bit 6
OFF
OFF
N/A
ON
OFF
RS-422
OFF
ON
RS-232
ON
ON
N/A
#T559795; r.21371/22369; en-US
16
Содержание A3xx pt series
Страница 1: ...User s manual FLIR A3xx pt series...
Страница 2: ......
Страница 3: ...User s manual FLIR A3xx pt series T559795 r 21371 22369 en US iii...
Страница 4: ......
Страница 8: ......
Страница 13: ...Customer help 4 4 1 General For customer help visit http support flir com T559795 r 21371 22369 en US 5...
Страница 124: ...Certificate of conformity 12 T559795 r 21371 22369 en US 116...
Страница 165: ......