background image

FRD-57 Remote Display LED, Technical Manual   

Rev.2.1, October 2018 

 

 

Page 5 of 8 

 

6  Connection Examples 

 

6.1  FRD-57 and FT-1x / FT-10 / FT-11x 

 

 

Operation port:  

RS232 

 

DIP Switch S1 (ON): 

2, 3, 4 (=9600, 8N1) 

 

Jumper: 

   

 

 
 
 

 

PIN connection:

 

 

 

 
 
 
 

 

FT-1x and FT-11x Settings for RS232 Port 

 

Parameter FT-1x 

Parameter FT-10 

Parameter FT-11x 

Explanation 

[000  1] 

[000  1] 

[111  CONST] 

Continuously  

[001  3] 

[001  3] 

[112  9600] 

9600 Baud 

[002  0] 

 --- 

 --- 

No Handshake 

[003  00] 

[003  00] 

[119  00] 

Adres 0 

[004  0] 

[004  0] 

[113  8]; [114  NO] 

8, N, 1 

[005  1] 

[005  1] 

[115  NO] 

Check sum 

 --- 

[006  1] 

 --- 

Carriage return 

 --- 

[007  0] 

 --- 

Line Feed 

 
 
 

6.2  FRD-57 and DAD14x.x / DAS72.1 / LDUxx.x  

 
  

 

Operation port:  

 

RS485 

 

DIP Switch S1 (ON): 

 

2, 3 (=9600, 8N1) 

 

 Jumper: 

 

 

 

 
 
 

 

PIN connection:

 

 

 

 
 
 
 

 

DAD14x.x; DAS72.1, LDUxx.x Settings for RS485 Port 

 

Parameter 

Explanation 

Baud rate 

9600 

Ser. Port 

485 

Adres  

 

 

 

FT-1x, FT-10, 

FT-11x 

Signal 

FRD-57 

Pin 2 

TxD 

Tx 

Pin 7 

GND 

SGND 

DAS, DAD, LDU 

72.1, 14x.x, xx.x 

Signal 

FRD-57 

Tx+ 

Tx+ 

Tx- 

Tx- 

Содержание FRD-57

Страница 1: ...FRD 57 Remote Display LED Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Страница 2: ...mation contained herein The information herein is believed to be both accurate and reliable FLINTEC however would be obliged to be informed if any errors occur FLINTEC cannot accept any liability for...

Страница 3: ...N MAKING CHECKS TESTS AND ADJUSTMENTS THAT MUST BE MADE WITH POWER ON FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT IN BODILY HARM WARNING FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PR...

Страница 4: ...chosen via serial port RS232 RS485 or 20mA current loop The remote display is designed in a stainless steel housing IP65 3 Specifications Display Display 6 digits red LED 7 segments 57 mm Point adjus...

Страница 5: ...e unused interfaces must not be connected There are two jumpers next to the connection terminal These are used to select the serial interface The communication parameters of the selected interface can...

Страница 6: ...Continuously 001 3 001 3 112 9600 9600 Baud 002 0 No Handshake 003 00 003 00 119 00 Adres 0 004 0 004 0 113 8 114 NO 8 N 1 005 1 005 1 115 NO Check sum 006 1 Carriage return 007 0 Line Feed 6 2 FRD 5...

Страница 7: ...FRD 57 Remote Display LED Technical Manual Rev 2 1 October 2018 Page 6 of 8 7 Dimensions...

Страница 8: ...FRD 57 Remote Display LED Technical Manual Rev 2 1 October 2018 Page 7 of 8 Bemannsbruch 9 D 74909 Meckesheim Deutschland Germany E Mail germany flintec com http www flintec com...

Отзывы: