6. Before connecting the unit to the power receptacle, 

check to insure there is no leakage to ground. This can 
be done by using an ohm meter and setting the scale to 
its highest setting (i.e. Rx100K). Connect one ohmmeter 
lead to the unit power cord ground (round prong) and 
to one of the flat prongs. It should read infinite or at 
least 2 mega ohms. Repeat with the other prong. If 
reading is below 2 mega ohms on either prong contact 
Customer Service Help Line listed at bottom of page.

7. 

Do Not Operate System on an Extension Cord.

 If no 

power is accessible at the pond, contract a licensed 
electrician to install the proper power supply in 
accordance with National Electric Code and all 
applicable local codes and ordinances.

8. After installing the unit, checking ground and 

connecting power to the unit, the unit can be powered 
up. Check operation of the GFI by pushing the “Test” 
button, the unit should stop. Pushing the “Reset” button 
should restart the unit. If pressing the “test” button 
does not stop the unit, immediately shut off power to 
unit and contact Customer Service Help Line listed at 
bottom of page.

NOZZLE PATTERNS

 

Th

is

 si

de

 up

IL0537

Th

is

 si

de

 up

Th

is

 si

de

 up

Figure 1: Water Lily - An eye-catching combination spray. 

Item #2C

 

Th

is

 si

de

 up

IL0537

Th

is

 si

de

 up

Th

is

 si

de

 up

Figure 2: Sky Cannon - A dramatic single plume of water. 

Item #2B

 

Th

is

 si

de

 up

IL0537

Th

is

 si

de

 up

Th

is

 si

de

 up

Figure 3: Water Trumpet - A symmetrical inverted bell shape. 

Item #2A

IL0535 

Pond Pump Float 
Nylon rope secured to weights
can be attached to stakes on 
shore. 2 Required.

5 Feet Minimum Depth 

Approved outdoor grounded 
receptacle with GFI protected plug 

Power cord may require 
burial. Refer to local codes 

15 - 20  

Feet 

Figure 4: Typical Installation

INSTALLATION CHECK LIST

 Read installation instructions and warnings

 Post appropriate warning signs

 Install desired spray nozzle

 Install and anchor unit in pond

 Check insulation resistance to ground

 Power up unit

 Test operation of GFI by pressing the “Test” Button.

 File instructions for future reference

REQUIRED TOOLS & SUPPLIES

• #2 Phillips screwdriver
• Nylon rope to anchor unit

• Stakes or weights for anchoring unit
• Ohm meter to check insulation resistance to ground

 

WINTER STORAGE

• Rinse unit with clean water to remove any build-up on 
unit.
• Check unit for any damage.
• Store unit in heated space in freezing climates. 
The pump motor is water lubricated and is factory filled 
with an antifreeze solution. During operation the antifreeze 
may exchange, thru the filtered check valve, with the pond 
water. In climates where freezing may occur, the unit must 
be stored in a heated storage space to prevent damage to 
the motor.

Содержание FPS0501

Страница 1: ...o comply with instructions could result in personal injury and or property damage Retain instructions for future reference General Safety Information Carefully read and follow all safety instructions in this manual and on pump Keep safety labels in good condi tion Replace missing or damaged safety labels This is a SAFETY ALERT SYMBOL When you see this symbol on the pump or in the manual look for o...

Страница 2: ...trol box fused disconnect switch or covers open either partially or completely when not being worked on by a competent electrician or repairman DANGER Always use caution when operating electrical controls in damp areas If possible avoid all contact with electrical equipment during thunderstorms or extreme damp conditions Install all electrical equipment in protected area to prevent mechanical dama...

Страница 3: ...Water Lily An eye catching combination spray Item 2C T h i s s i de up IL0537 T h i s s i de up T h i s s i de up Figure 2 Sky Cannon A dramatic single plume of water Item 2B IL0537 T h i s s i T h i s s i de up Figure 3 Water Trumpet A symmetrical inverted bell shape Item 2A IL0535 Pond Pump Float Nylon rope secured to weights can be attached to stakes on shore 2 Required 5 Feet Minimum Depth App...

Страница 4: ...or rope loose Check anchor rope and re attach if necessary Item Qty Part No Description 6 Screw 10 x 3 4 Slotted Head or Pan Head Sheet Metal Screw 18 8 Stainless Steel 2A 1 021617 Nozzle Water Trumpet 2B 1 021618 Nozzle Sky Cannon 2C 1 021619 Nozzle Water Lily 3 1 021622 O Ring AS568A 041 3 ID x 3 18 OD 4 6 021628 Bolt SS 1 4 20 x 3 4 5 6 021629 Lockwasher 1 4 6 1 021707 Mounting Flange 7 1 02291...