Flexzilla FI05V080Y1S Скачать руководство пользователя страница 4

Opera ng Instruc ons

 

Forkli  Safety

 

1. Make sure li  operator stays aware while

moving compressor.

2. Be sure load is secure and well balanced

before moving the compressor.

3. Make sure forks are fully engaged and  level

before li ing or moving  compressor.

4. Keep load as low as possible and observe

safe opera ng prac ces.

Figure 1: Keep unit level 

Li ing Safety

 

1. Carefully inspect all li ing equipment and make 

sure it is in good condi on. Rated capacity should

exceed compressor weight. Make sure li ing hook

has a func onal safety latch or equivalent and is

properly a ched to li ing feature.

2. Make sure li ing points are in good condi on and

hten any loose nuts or bolts before li ing.

3. Use provided li ing feature or appropriate sling. A

sling must be used when moving compressor with a

helicopter or other air-borne equipment. Be sure to

follow OSHA standards 29 CFR 1910 Subpart N.

4. Use guide ropes or equivalent to prevent twis ng

or swinging of the compressor while it is in the 

air and NEVER a empt to li  in high winds. Keep

compressor as low to the ground as possible.

5. Keep persons away and make sure no one is under

the compressor while it is  li ed.

6. Only use li ing features provided for en

 com- 

pressor package. NEVER use bolts or other hooks on

invididual components to move the compressor.

7. Make sure to put compressor on a level surface that

can support the weight of the compressor and load- 

ing equipment.

Do not operate unit if damaged 

during shipping, handling or  use.

 

Damage may result in burs ng and cause injury  or 

property damage.

 

Installa on

 

Area

 

1. Install compressor in a clean, dry and well-lit

area. Be sure installa on area can  maintain

a temperature range between 35

˚

 - 110

˚

 F. 

If ambient temperature drops 

below 32

˚

F, be sure to protect

 

safety/relief valves and drain valves from  freezing. 

NEVER operate compressor with temperatures 

below 15

˚

F or above  125

˚

F.

 

2. Allow su

cient space around compressor for

maintenance access and adequate air

ow.

Mount unit with pulley towards wall and

leave a minimum of 15 inches of clearance.

3. Use shims to level compressor if installa on

area is not 

at. This will avoid  excessive

vibra on and premature pump wear.

DO NOT install compressor in boiler 

room, paint spray room  or area 

where sandblas ng occurs. Make 

sure inlet air is away from  exhaust 

fumes or other toxic, noxious or 

corrosive fumes or substances.

 

4. If acid is used in opera ng environment or  

  air

is dust laden, pipe intake to outside, fresh air.

Increase pipe size by one size for every 20  feet

of run. Be sure to install protec ve hood  around

intake 

lter.

5. In opera ng environments where excessive wa- 

ter, oil, dirt, acid or alkaline fumes are  present,

a TEFC (totally enclosed, fan- cooled) motor is

recommended. Check nameplate for motor type.

6. Insulate cold water or other low temperature 

pipes that pass overhead to avoid condensa on 

dripping on compressor which could cause rust

and/or motor shor ng.

Piping 
Safety Steps

 

1. Install appropriate 

ow-limi ng valves as nec- 

essary according to pipe size(s) used and  run

lengths. This will reduce pressure in case of hose 

failure, per OSHA Standard 29 CFR 1926.302(b)(7).

2. Flow-limi ng valves are listed by pipe size  and 

rated CFM. Select appropriate valves accordingly,

in accordance with the manufacturer’s recommen- 

da ons. 

 

TO ACTIVATE

WARRANTY

Scan or go to 

for warranty registration

Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual.

Содержание FI05V080Y1S

Страница 1: ...are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in opera on Keep these instru ons for reference 1811 Operating Instructions Warr...

Страница 2: ...30 460 575 APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T 640 640 800 800 800 800 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 735 735 752 752 1190 1190 956 956 988 956 1200 1200...

Страница 3: ...xcept in full compliance with OSHA Standards 29 CFR 1910 and any other Federal State or Local codes or regula ons Death or serious injury can result from inhaling compressed air without using proper s...

Страница 4: ...n a temperature range between 35 110 F Ifambienttemperaturedrops below 32 F be sure to protect safety relief valves and drain valves from freezing NEVER operate compressor with temperatures below 15 F...

Страница 5: ...top to minimize condensa on in air drop ELEVATION Watertrap with drain Air Tank Air Dryer From Compressor To Air Tool Water Drain Valve Figure 2 Basic Piping Diagram Never install a shut o valve such...

Страница 6: ...circuit can cause circuit overload and or imbalance in motor phasing Install proper No Fuse Breaker NFB according to kW output of compressor 3 Ensure incoming service has adequate ampere ra ng 4 Ensu...

Страница 7: ...220V or 460V Opera on SafetyRules 1 Make sure all operators receive product train ing and read and understand all instruc ons Keep all ammable combus ble poisonous and noxious materials away from oper...

Страница 8: ...liminate numerous motor starts stops and to help coolpump To engage con nuous run feature open ball valve found by following copper tubing across cylinder heads to tank See gure 9 Stop con nuous run f...

Страница 9: ...comes milky Safety Valve NEVER a empt to regulate or tamper with safety valve Valve is sealed and cer ed by ASME code and is designed to relieve system pressurewhennecessary Check proper opera on of s...

Страница 10: ...clockwiserota on 3 Clean or replace 4 Replace gasket s 5 Clear blockage 6 Add oil Ensure oil level is at middle of site glass See gure 8 Use only Flexzilla Compressor Oil Use of any other product will...

Страница 11: ...r unit If the unit runs out of oil this warranty is void Failure to fully comply with this warranty and fully comply with the manual herein will also void this warranty WEEMS GLOBAL WARRANTY EXCLUSION...

Отзывы: