Flexzilla FI05V080Y1S Скачать руководство пользователя страница 2

Flexzilla 

Electric Operated, Piston Compressors

 

Flexzilla Electric operated, Two Stage, 5-10 HP Piston Air Compressors

 
 
 
 

Tank Type

 

Dimensions 

(LxWxH inches)

Tank Size

 

 

 

CFM @ 100 psi

Max PSI
Motor HP

 

Motor RPM
Voltage
Pump Model
Pump RPM

Weight (±5 lbs.)
Shipping Weight

MODEL 

 

 

FXS10V080V1 

 

FXS10V120V1           FXS10V120V3-208

FI05V080Y1S

 

FXS07V080V3-208

 

 

FXS10V080V3-208

 

 

FXS10V120V3-230

 

FXS07V080V3-230

 

 

FXS10V080V3-230

 

 

FXS10V120V3-460

 

FXS07V080V3-460

 

 

FXS10V080V3-460

 

 

FXS10V120V3-575

 

FXS07V080V3-575

 

 

FXS10V080V3-575

 

 

 

34 x 42 x 72 

34 x 42 x 72 

38 x 42 x 72  

38 x 42 x 72 

41 x 43 x 78 

41 x 43 x 78

80 Gallon 

80 Gallon 

80 Gallon 

80 Gallon 

120 Gallon 

120 Gallon

7.5 HP 

7.5 HP 

10 HP 

10 HP 

10 HP 

10 HP

Single Phase 

Three Phase 

Single Phase  

Three Phase 

Single Phase 

Three Phase

 

31  

31  

38  

38 

38 

38

 

175 

175 

175  

175 

175 

175

7.5 HP 

7.5 HP 

10 HP 

10 HP 

10 HP 

10 HP

 

1750 

1750 

1750  

1750 

1750 

1750

 

208V/230V 

208/230/460/575 

208V/230V  

208/230/460/575 

208V/230V 

208/230/460/575

 

APP4V1043T 

APP4V1043T 

APP4V1043T  

APP4V1043T 

APP4V1043T 

APP4V1043T

 

640 

640 

800  

800 

800 

800

 

NPT 3/4” 

NPT 3/4” 

NPT 3/4” 

NPT 3/4” 

NPT 3/4” 

NPT 3/4”

 

735 

735 

752 

752 

1190 

1190

 

956  

956  

988  

956  

1200 

1200

34 x 39 x 69

80 Gallon

5 HP

Single Phase

18

CFM @ 175 psi

26

26

34

34

34

34

14

145

5 HP

3450

APP3Y0732T

776

230V

680

NPT 3/4”

576

FXS07V080V1

Contents

Warranty Activation

...................................................... 2

Model Specification Charts

............................................ 2

Description

....................................................................... 2

Safety Information

........................................................... 3

 

Tag Definitions.............................................................. 3

 

Basic Guidelines........................................................... 3

 

Breathable Air............................................................... 3

 

Pressurized Components............................................. 3

 

Personal Protective Equipment .................................... 3

Inspection

......................................................................... 3

 

Forklift Safety  .............................................................. 4

 

Lifting Safety ................................................................ 4

Installation

........................................................................ 4

 

Area ............................................................................. 4

 

Piping Safety  ............................................................... 4

 

Piping / Tank Installation............................................... 5

 

Electronic Auto Drain (if equipped)............................... 5

 

Electrical Safety ........................................................... 6

 

Wiring Installation......................................................... 6

Operation

.......................................................................... 7

 

Safety Rules ................................................................. 7

 

Start Up........................................................................ 8

 

Continuous Run Feature .............................................. 8

Maintenance

..................................................................... 8

 

Safety Steps ................................................................. 8

 

Belt Adjustment ............................................................ 9

 

Changing Oil................................................................. 9

 

Safety Valve.................................................................. 9

 

Tank.............................................................................. 9

Maintenance Schedule

 ................................................. 10

Troubleshooting

 ............................................................ 10

Warranty

......................................................................... 11

TO ACTIVATE WARRANTY

Scan or go to 

for warranty 

Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual.

registration

Содержание FI05V080Y1S

Страница 1: ...are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in opera on Keep these instru ons for reference 1811 Operating Instructions Warr...

Страница 2: ...30 460 575 APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T 640 640 800 800 800 800 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 735 735 752 752 1190 1190 956 956 988 956 1200 1200...

Страница 3: ...xcept in full compliance with OSHA Standards 29 CFR 1910 and any other Federal State or Local codes or regula ons Death or serious injury can result from inhaling compressed air without using proper s...

Страница 4: ...n a temperature range between 35 110 F Ifambienttemperaturedrops below 32 F be sure to protect safety relief valves and drain valves from freezing NEVER operate compressor with temperatures below 15 F...

Страница 5: ...top to minimize condensa on in air drop ELEVATION Watertrap with drain Air Tank Air Dryer From Compressor To Air Tool Water Drain Valve Figure 2 Basic Piping Diagram Never install a shut o valve such...

Страница 6: ...circuit can cause circuit overload and or imbalance in motor phasing Install proper No Fuse Breaker NFB according to kW output of compressor 3 Ensure incoming service has adequate ampere ra ng 4 Ensu...

Страница 7: ...220V or 460V Opera on SafetyRules 1 Make sure all operators receive product train ing and read and understand all instruc ons Keep all ammable combus ble poisonous and noxious materials away from oper...

Страница 8: ...liminate numerous motor starts stops and to help coolpump To engage con nuous run feature open ball valve found by following copper tubing across cylinder heads to tank See gure 9 Stop con nuous run f...

Страница 9: ...comes milky Safety Valve NEVER a empt to regulate or tamper with safety valve Valve is sealed and cer ed by ASME code and is designed to relieve system pressurewhennecessary Check proper opera on of s...

Страница 10: ...clockwiserota on 3 Clean or replace 4 Replace gasket s 5 Clear blockage 6 Add oil Ensure oil level is at middle of site glass See gure 8 Use only Flexzilla Compressor Oil Use of any other product will...

Страница 11: ...r unit If the unit runs out of oil this warranty is void Failure to fully comply with this warranty and fully comply with the manual herein will also void this warranty WEEMS GLOBAL WARRANTY EXCLUSION...

Отзывы: