3. OPERATION
3.1 Test Run
Before using the air compressor for the first time
complete a test run as follows:
1.)
Turn the power switch to the OFF position.
Plug the power supply cord into a power supply
socket.
Start the air compressor by turning the power
switch to the ON position.
The pressure gauge reading will slowly rise as
pressure increases inside the air tank.
When the gauge reading reaches 120 PSI – 125 PSI,
the pressure switch will automatically turn the
power off.
This indicates the compressor is working normally.
2.)
Turn the power switch to the OFF position, unplug
the power supply cord and release the air in the
tank by pulling on the safety valve. At this point
proceed to the next step.
Note:
If the air compressor is not working properly,
the pressure gauge will indicate that there is a
decrease in pressure in the air tank. If there is an
air leak from the compressor the pressure in the
air tank decreases, the pressure switch resets and
the motor automatically turns back on.
If you detect an air leakage, turn the power switch
to the OFF position, release the air from the tank
by pulling on the safety valve. Unplug the power
supply cord and contact Customer Support for
assistance.
3.2 Daily Operation
Starting the compressor:
1.)
Turn the power switch to the OFF position.
2.)
Attach air hose to the 1/4” Universal/Industrial
Quick Connector.
3.)
Check that all air fittings are tight and close manual
drain valve.
4.)
Maintain 2 feet of open space around the air
compressor.
5.)
Plug the power supply cord into a 110V 20 amp
outlet/breaker.
6.)
Turn the power switch to the ON position.
7.)
Let the motor run and tank fill until motor
turns off.
8.)
To regulate air flow. While the air compressor is
running, turn on your tool and turn the regulator
knob to the right increasing the pressure.
Turn the pressure up until the desired pressure is
reached.
9.)
Operate air tool normally. Do not use continuously
(running) for more than (8-12) hours.
2. SET UP INSTRUCTIONS
2.1 Initial Set Up
1.)
Read safety warnings before setting up air
compressor.
2.2 Location
1.)
In order to avoid damaging the air compressor,
do not incline the air compressor transversely or
longitudinally more than 10°.
2.)
Place air compressor at least 2 feet away from
obstacles that may prevent proper ventilation.
Do not place air compressor in an area:
a. Where there is evidence of oil or gas leaks.
b. Where flammable gas vapors or materials may
be present.
c. Where air temperatures fall below 32°F or
exceed 104°F.
d. Where extremely dirty air or water could be
drawn into the air compressor.
2.3 Electrical
1.) USE OF AN EXTENSION CORD IS NOT RECOMMENDED
because it could cause the compressor motor to
overheat. It’s preferable to use additional air hose
instead of an extension cord.
2.)
If use of an extension cord is unavoidable, be
sure to use one heavy enough to carry the current
your compressor will draw. Minimum cord sizes are
as follows:
Ampere
Rating
Range
Voltage
Length of cord in ft.
120V
25 ft.
50 ft
100 ft.
150 ft.
200 ft.
250 ft.
240V
50 ft.
100 ft.
200 ft.
300 ft.
400 ft.
500 ft.
8 - 10
18
14
12
10
8
8
10 - 12
16
14
10
8
8
6
12 - 14
16
12
10
8
6
6
14 - 16
16
12
10
8
6
6
16 - 18
14
12
8
8
6
4
18 - 20
14
12
8
6
6
4
3.)
Use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will
accept the plug of the compressor.
4.)
Examine cords before using. Do not use the
compressor if its cord is damaged. Do not use a
damaged extension cord.
5.)
Keep cords away from heat and sharp edges. Do
not pull on a cord to disconnect a plug – grasp
the plug.
6.)
Always shut off the compressor pressure switch
before unplugging the compressor.