![FlexRadio Systems Power Genius XL Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/flexradio-systems/power-genius-xl/power-genius-xl_user-manual_2305007008.webp)
1
AC Power input:
standard 120V or 220V AC used to power the amplifier.
2
RF Precorrector B output:
-60dBc output signal, for connecting to a radio
precorrector. (if radio has one)
3
PTT output B:
standard RCA connector. It outputs GND as a PTT signal. Can be
configured to +12V by internal jumper. Pins are isolated with optocouplers.
4
RF output B:
standard PL259 type connector for connecting your antenna.
5
RF output A:
standard PL259 type connector for connecting your antenna.
6
RF input A:
standard PL259 type connector for connecting your transceiver.
7
RF input B:
standard PL259 type connector for connecting your transceiver.
8
PTT input B:
standard RCA connector. It expects GND as a PTT signal. Can be
configured to +12V by internal jumper.
9
Chassis Ground:
#8 Thumb screw
10
RF Precorrector A output:
-60dBc output signal, for connecting to a radio
precorrector. (if radio has one)
11
PTT output A:
standard RCA connector. It outputs GND as a PTT signal. Can be
configured to +12V by internal jumper. Pins are isolated with optocouplers.
12
Ethernet connector –
Not in use. Reserved for a future upgrade.
13
CI-V input B:
standard 3.5mm stereo connector for ICOM radio band data.
Pins are isolated with optocouplers.
14
BCD/PTP input B:
standard female DB15 connector for radio band data.
Pins are isolated with optocouplers.
15
CAT input B:
standard male DB9 type connector for radio CAT connection.
Pins are isolated with optocouplers.
16
CI-V input A:
standard 3.5mm stereo connector for ICOM radio band data.
Pins are isolated with optocouplers.
17
CAT input A:
standard male DB9 type connector for radio CAT connection.
Pins are isolated with optocouplers.
18
BCD/PTP input A:
standard female DB15 connector for radio band data.
Pins are isolated with optocouplers.
19
PTT input A:
standard RCA connector. It expects GND as a PTT signal. Can be
configured to +12V by internal jumper. Pins are isolated with optocouplers.
20
Power Switch:
Turn the amplifier ON or OFF.
▲
Index
8/23
Содержание Power Genius XL
Страница 1: ...Power Genius XL User Manual rev 10 Index 1 23...
Страница 20: ...6 Alarms 6 1 High SWR alarm Release PTT to dismiss the alarm message 6 2 Id alarm Index 20 23...
Страница 21: ...6 3 Fan failure alarm 6 4 Power supply failure alarm Index 21 23...
Страница 23: ...In case the display module looses communication with the main processor Try rebooting the amplifier Index 23 23...