Air to water heat pump operation manual
P4
time setting canceld
2
2
2
2
.
.
.
.
5
5
5
5 Clock
Clock
Clock
Clock setting
setting
setting
setting
:
press “timer”key for 3s, hear a “toot” voice, press continuingly, after press the “timer”key for 8s,
when hear “toot” voice again, then move away finger, enter clock setting state,
First adjust the “hour ” of clock, press “timer” key again, then adjust “minute” of clock, press “timer” key
again, then finish setting and quit setting.
Note: clock setting just can be operated under the condition of there isn’t definite time set.
2
2
2
2
.
6
6
6
6 Force
Force
Force
Force defrosting
defrosting
defrosting
defrosting
:
after the heat pump was power on and the compressor has started, then press
“▼ ”
over 8s,
when hear a “toot” voice, move away finger, then enter defrost state, when the temperature of coil
(
evaporator
)
or
defrosting time reach preset parameter, then quit defrost.
2
2
2
2
.
7
7
7
7 Cooling
Cooling
Cooling
Cooling mode
mode
mode
mode
:
Under heating water mode, press “
▲
”
key over 8s, then hear a “toot” voice, enter cooling
mode. Range of water temperature adjusting: 7
℃
-30
℃,
under cooling
mode, then press
“
▲
”
over 8s,
enter heating mode.
Parameter setting and inquiry
(
attached table 1
)
A
A
A
A
:
function
function
function
function inquiry
inquiry
inquiry
inquiry
Under power on state, press “setting” key, inquiry code is from A1 to A9, if single compressor heat pump,
press “setting” key again, then quit inquiry state, if double compressor heat pump, another 9 inquiry code
can be inquired, from b1 to b9, press “setting” key again, quit inquiry state. Please check following stable
:
B
B
B
B
:
function
function
function
function setting
setting
setting
setting
Under power on state, press “setting” key over 3s, when hear “toot” voice ,move away finger,
enter parameter setting state, after parameter set, press “setting” key ,enter next parameter
setting, until all the setting of parameters are finished ,then quit setting.
Inquiry code
Meaning( single compressor
Heat pump)
Meaning( double syst
Code
Meaning( double syst)
A1
Coil(evaporator) temperature
Coil(evaporator)
temperature 1
b1
Coil(evaporator)
temperature
2
A2
Return gas temperature
Return gas temperature1
b2
Return gas temperature 2
A3
Exhaust temperature
Exhaust temperature 1
b3
Exhaust temperature 2
A4
Environment temperature
Environment temperature
b4
Environment temperature
A5
Outlet water temperature
Outlet water temperature
b5
Outlet water temperature
A6
Return water temperature
Return water temperature
b6
Return water temperature
A7
00
00
b7
00
A8
Compressor current
Compressor current 1
b8
Compressor current 2
A9
Opening angle of
expansion valve
Opening angle of
expansion valve1
b9
Opening angle of
expansion valve1
Er
Display of error code
Display of error code
Er
Display of error code
Set code
Parameter name
range
Initial
/
/
/
Water tank temperature
20
℃─
60
℃
50
℃
L1
Temp differentce between water
tank real temp and display temp
0
℃─
15
℃
0
℃
L2
Temp difference between compressor stard restart
temp and preset water tank temp
3
℃─
18
℃
5
℃