FLEXPOWER TWO VFXR Series Скачать руководство пользователя страница 1

Components

Setup and Programming

Contact Technical Support:

Telephone:

+1.360.618.4363

Email:  

[email protected]

Website:  

www.outbackpower.com

> 90% (blinks if charge parameters are met)

Color

Red

Yellow

Yellow

Yellow

Green

 80%

 70% 

 60% 

 60% off, < 60% solid, < 50% blinks

Battery State-of-Charge

FN-DC LED Indicators

Phase

Active

Error

DC

AC IN

AC OUT

Red

Yellow

Yellow

Yellow

Red

Red

Surge Protector LEDs

LED Indicators on the Inverter

Inverter Status LED Indicators

Green

Yellow

Red

Inverter on (solid) or standing by (flash)

AC source in use (solid) or standing by (flash)

Inverter error or warning (see manual)

Green

Yellow

Red

12.5 Vdc or higher 

11.5 to 12.4 Vdc 

11.4 Vdc or lower 

Color

Battery Status LED Indicators

25.0 Vdc or higher 

23.0 to 24.8 Vdc 

22.8 Vdc or lower 

50.0 Vdc or higher 

46.0 to 49.6 Vdc 

45.6 Vdc or lower 

12 V Inverter

24 V Inverter

48 V Inverter

AC Enclosure

DC Enclosure

Charge Controller

(FLEXmax 80 x2)

FLEXnet DC

Battery Monitor

Surge Protector 

(Inside)

Inverter/Charger x2

System Display 

and 

Controller 

(MATE3)

HUB 

Communications 

Manager 

Battery Status and Inverter Status 

LED Indicators

AC Source

Utility Grid or AC Generator 

Main Electrical Panel (or overcurrent device for the AC source)

Battery Bank

Photovoltaic (PV) Array (with PV Combiner Box)

Customer-Supplied Components

Electrical Distribution Subpanel (Load Panel)

Inverter/Chargers (x2)

AC Conduit Box 

(with Bypass Assembly)

DC Enclosure Box 

(with Inverter Circuit Breaker) 

System Display and Controller

Communications Manager 

Remote Temperature Sensor (RTS)

FLEXpower System Products 

Major Components

Charge Controller

Balancing Transformer

FLEXnet DC Monitor (FN-DC)

Surge Protector  

IMPORTANT:  

Not intended for use with 

life support equipment.

900-0158-01-0

0

 REV 

B

.vsd

©2013 OutBack Power Technologies.  All Rights Reserved.

Supports the OPTICS RE™ online tool for a cloud-based remote monitoring and control application.  
Please refer to the OPTICS RE setup instructions, or visit www.outbackpower.com to download.

The firmware revision of all 
devices can be confirmed by 
navigating from the MATE3 
Main Menu as shown below.  
Upgrades to the firmware 
revision can be downloaded 
from the OutBack website 
www.outbackpower.com.

Firmware Revision

Configuration Wizard

The MATE3 Configuration Wizard allows quick setup of parameters that apply to all systems.  The Configuration Wizard is reached from 
the MATE3 Main Menu as shown below.

Note: 

 See the MATE3 

manual for details on 
generator control.

Off Grid

Grid Tied

Backup

The 

Continue 

key advances the display 

to the 

Setup Complete 

screen if the 

FLEXnet DC is not installed.  If the 
FLEXnet DC is installed, the display 
advances to the 

Shunt 

screens.

Configuration Wizard

           New Configuration           >>
           Existing Configuration      >>
           Restore Configuration       >> 
 

Wizard System Type

System Type         Grid Tied    
System Voltage      48 VDC
Array Wattage     1000
Battery Type       FLA   Capacity  500 Ah   
  Back                            Continue

Wizard Battery Charging

Absorb Voltage    57.6 VDC     Time  1.0
Float Voltage     54.4 VDC     Time  1.0
Equalize Voltage  60.0 VDC     Time  3.0
Re-Float Voltage  44.0 VDC
  Back                            Continue

Configuration Wizard

         

New Configuration Initialized

            

 

Back                          Continue

Wizard Grid Use Schedule

            Period 1 Enable  N
        Weekday Use  0:00  Drop 0:00
        Weekend Use  0:00  Drop 0:00            
 

Back                            Continue

Wizard Grid Use Schedule

        Period 2 Enable  N
        Weekday Use  0:00  Drop 0:00
                   
 

Back                            Continue

Wizard Grid Use Schedule

        Period 3 Enable  N
        Weekday Use  0:00  Drop 0:00
                   
 

Back                            Continue

Wizard Battery Monitor

        Shunt B
        Connection  Charge Controller

            

 Back                             Continue

Wizard Grid Use Schedule

        Period 3 Enable  N
        Weekday Use  0:00  Drop 0:00
                   
 

Back                            Continue

Wizard High Battery Transfer

Mode Disabled
Grid Connect     48.0 VDC   Delay 60 Min
Grid Disconnect  52.0 VDC   Delay 60 Min
Grid Connect SOC 60%   Disconnect SOC 95%

Back                            Continue

Wizard Grid Use Schedule

        Period 1 Enable  N
        Weekday Use  0:00  Drop 0:00
        Weekend Use  0:00  Drop 0:00            
 

Back                            Continue

Wizard Generator Configuration

Generator Installed     N
Generator Type          AC   Size  5.0 kW 
Generator Start         Manual
AUX Output Device Port 1

Back                            Continue

Wizard AC Configuration

AC Output Voltage 230 VAC    
AC Phase          Single
AC Input Breaker Size 50 A
Maximum Output Load   30 A 

Back                            Continue

Wizard Grid Use Schedule

        Period 2 Enable  N
        Weekday Use  0:00  Drop 0:00
                   
 

Back                            Continue

Wizard Generator Configuration

Generator Installed     N
Generator Type          AC   Size  5.0 kW 
Generator Start         Manual
AUX Output Device Port 1

Back                            Continue

Wizard Battery Charging

Absorb Voltage    57.6 VDC     Time  1.0
Float Voltage     54.4 VDC     Time  1.0
Equalize Voltage  60.0 VDC     Time  3.0
Re-Float Voltage  44.0 VDC

Back                            Continue

Wizard AC Configuration

AC Output Voltage 230 VAC    
AC Phase          Single
AC Input Breaker Size 50 A
Maximum Output Load   30 A

Back                            Continue

Wizard System Type

System Type         Backup    
System Voltage      48 VDC
Array Wattage     1000
Battery Type       FLA   Capacity  500 Ah 

Back                            Continue

Wizard Battery Monitor

        Shunt A
        Connection  Inverter           
 

Back                             Continue

Wizard AC Configuration

AC Output Voltage 230 VAC    
AC Phase          Single
AC Input Breaker Size 50 A
Maximum Output Load   30 A

Back                            Continue

Wizard Battery Charging

Absorb Voltage    57.6 VDC     Time  1.0
Float Voltage     54.4 VDC     Time  1.0
Equalize Voltage  60.0 VDC     Time  3.0
Re-Float Voltage  44.0 VDC

Back                            Continue

Wizard System Type

System Type         Off Grid    
System Voltage      48 VDC
Array Wattage     1000
Battery Type       FLA   Capacity  500 Ah 

Back                            Continue

Main Menu

Settings                    >>
Configuration Wizard        >>
Device Data Logs            >>
Event Logs                  >>
Firmware Update             >>

Configuration Wizard

New Configuration 

Settings Menu
System                    >>
Inverter                  >>
Charge Controller         >>
Battery Monitor           >>
MATE3                     >>

System

System Configuration

System Information        >>
Save / Store Information  >>
Firmware Version          >>
Date and Time             >>
LCD Display               >>

Firmware Versions

                MATE3     003.002.005
           1:   VFXR3048E 001.006.002
           2:   VFXR3048E 001.006.002        
          
          

Main Menu

Settings                  >>
Configuration Wizard      >>
Device Data Logs          >>
Event Logs                >>
Firmware Update           >>

Settings

!

CAUTION:  Equipment Damage

These procedures should be done by a qualified installer who is trained on programming inverter power systems. Failure to set 
accurate parameters for the system could potentially cause equipment damage.  Damage caused by inaccurate programming is 
not covered by the limited warranty for the system.

IMPORTANT

Check the firmware revision of all OutBack devices before use.  The MATE3 system display must be revision 003.002.xxx or 
higher.  If the revision is lower, the MATE3 and inverter may not communicate or operate correctly.    

Wizard High Battery Transfer

Mode Disabled
Grid Connect     48.0 VDC   Delay 60 Min
Grid Disconnect  52.0 VDC   Delay 60 Min
Grid Connect SOC 60%   Disconnect SOC 95%

Back                           Continue

Wizard Generator Configuration

Generator Installed     Y
Generator Type          AC   Size  5.0 kW 
Generator Start         Manual
AUX Output Device Port 1

Back                            Continue

Wizard Battery Monitor

        Shunt C
        Connection  Charge Controller

            

 Back                             Continue

Содержание TWO VFXR Series

Страница 1: ... 2 Enable N Weekday Use 0 00 Drop 0 00 Back Continue Wizard Grid Use Schedule Period 3 Enable N Weekday Use 0 00 Drop 0 00 Back Continue Wizard Battery Monitor Shunt B Connection Charge Controller Back Continue Wizard Grid Use Schedule Period 3 Enable N Weekday Use 0 00 Drop 0 00 Back Continue Wizard High Battery Transfer Mode Disabled Grid Connect 48 0 VDC Delay 60 Min Grid Disconnect 52 0 VDC De...

Страница 2: ...verter Chassis Ground DC Positive Plate 17 18 19 Charge Controller Chassis Ground 20 DC Negative Plate 17 18 19 19 20 20 Surge Protector CC Communication Ports 21 22 23 FN DC Communication Port 24 Inverter Communication Ports 21 21 22 22 23 23 24 FP2 Mounting 1 Ensure the mounting surface is strong enough to handle 3 times the total weight of all the components 2 Using additional people to assist ...

Страница 3: ... breakers 2 Turn off open the DC circuit breakers for the battery Wait 5 minutes for the devices to internally discharge themselves 3 Turn off open the PV circuit breakers 4 Turn off open the GFDI circuit breaker 5 Verify 0 Vdc on the DC input terminal of the master inverter by placing the voltmeter leads on and 6 Verify 0 Vdc on the DC input terminal of the slave inverter by placing the voltmeter...

Страница 4: ... OFF O O F F O FAULT PV INACTIVE NORMAL PV ACTIVE PV ARRAY GROUND FAULT DETECTOR INTERRUPTER GROUND FAULT PV ARRAY General Wiring O I O I O I O I O I O I O I O I O I O I O I O I AC Source Ground Electrode System Ground Rod 900 0158 01 00 REV B vsd 2013 OutBack Power Technologies All Rights Reserved PV Array 1 Battery Bank Vented Battery Enclosure AC Distribution Panel PV Array 2 PV Combiner Box Ch...

Отзывы: