Components
Setup and Programming
Contact Technical Support:
Telephone:
+1.360.618.4363
Email:
Website:
www.outbackpower.com
> 90% (blinks if charge parameters are met)
Color
Red
Yellow
Yellow
Yellow
Green
≥
80%
≥
70%
≥
60%
≥
60% off, < 60% solid, < 50% blinks
Battery State-of-Charge
FN-DC LED Indicators
Phase
Active
Error
DC
AC IN
AC OUT
Red
Yellow
Yellow
Yellow
Red
Red
Surge Protector LEDs
LED Indicators on the Inverter
Inverter Status LED Indicators
Green
Yellow
Red
Inverter on (solid) or standing by (flash)
AC source in use (solid) or standing by (flash)
Inverter error or warning (see manual)
Green
Yellow
Red
12.5 Vdc or higher
11.5 to 12.4 Vdc
11.4 Vdc or lower
Color
Battery Status LED Indicators
25.0 Vdc or higher
23.0 to 24.8 Vdc
22.8 Vdc or lower
50.0 Vdc or higher
46.0 to 49.6 Vdc
45.6 Vdc or lower
12 V Inverter
24 V Inverter
48 V Inverter
AC Enclosure
DC Enclosure
Charge Controller
(FLEXmax 80 x2)
FLEXnet DC
Battery Monitor
Surge Protector
(Inside)
Inverter/Charger x2
System Display
and
Controller
(MATE3)
HUB
Communications
Manager
Battery Status and Inverter Status
LED Indicators
AC Source
Utility Grid or AC Generator
Main Electrical Panel (or overcurrent device for the AC source)
Battery Bank
Photovoltaic (PV) Array (with PV Combiner Box)
Customer-Supplied Components
Electrical Distribution Subpanel (Load Panel)
Inverter/Chargers (x2)
AC Conduit Box
(with Bypass Assembly)
DC Enclosure Box
(with Inverter Circuit Breaker)
System Display and Controller
Communications Manager
Remote Temperature Sensor (RTS)
FLEXpower System Products
Major Components
Charge Controller
Balancing Transformer
FLEXnet DC Monitor (FN-DC)
Surge Protector
IMPORTANT:
Not intended for use with
life support equipment.
900-0158-01-0
0
REV
B
.vsd
©2013 OutBack Power Technologies. All Rights Reserved.
Supports the OPTICS RE™ online tool for a cloud-based remote monitoring and control application.
Please refer to the OPTICS RE setup instructions, or visit www.outbackpower.com to download.
The firmware revision of all
devices can be confirmed by
navigating from the MATE3
Main Menu as shown below.
Upgrades to the firmware
revision can be downloaded
from the OutBack website
www.outbackpower.com.
Firmware Revision
Configuration Wizard
The MATE3 Configuration Wizard allows quick setup of parameters that apply to all systems. The Configuration Wizard is reached from
the MATE3 Main Menu as shown below.
Note:
See the MATE3
manual for details on
generator control.
Off Grid
Grid Tied
Backup
The
Continue
key advances the display
to the
Setup Complete
screen if the
FLEXnet DC is not installed. If the
FLEXnet DC is installed, the display
advances to the
Shunt
screens.
Configuration Wizard
New Configuration >>
Existing Configuration >>
Restore Configuration >>
Wizard System Type
System Type Grid Tied
System Voltage 48 VDC
Array Wattage 1000
Battery Type FLA Capacity 500 Ah
Back Continue
Wizard Battery Charging
Absorb Voltage 57.6 VDC Time 1.0
Float Voltage 54.4 VDC Time 1.0
Equalize Voltage 60.0 VDC Time 3.0
Re-Float Voltage 44.0 VDC
Back Continue
Configuration Wizard
New Configuration Initialized
Back Continue
Wizard Grid Use Schedule
Period 1 Enable N
Weekday Use 0:00 Drop 0:00
Weekend Use 0:00 Drop 0:00
Back Continue
Wizard Grid Use Schedule
Period 2 Enable N
Weekday Use 0:00 Drop 0:00
Back Continue
Wizard Grid Use Schedule
Period 3 Enable N
Weekday Use 0:00 Drop 0:00
Back Continue
Wizard Battery Monitor
Shunt B
Connection Charge Controller
Back Continue
Wizard Grid Use Schedule
Period 3 Enable N
Weekday Use 0:00 Drop 0:00
Back Continue
Wizard High Battery Transfer
Mode Disabled
Grid Connect 48.0 VDC Delay 60 Min
Grid Disconnect 52.0 VDC Delay 60 Min
Grid Connect SOC 60% Disconnect SOC 95%
Back Continue
Wizard Grid Use Schedule
Period 1 Enable N
Weekday Use 0:00 Drop 0:00
Weekend Use 0:00 Drop 0:00
Back Continue
Wizard Generator Configuration
Generator Installed N
Generator Type AC Size 5.0 kW
Generator Start Manual
AUX Output Device Port 1
Back Continue
Wizard AC Configuration
AC Output Voltage 230 VAC
AC Phase Single
AC Input Breaker Size 50 A
Maximum Output Load 30 A
Back Continue
Wizard Grid Use Schedule
Period 2 Enable N
Weekday Use 0:00 Drop 0:00
Back Continue
Wizard Generator Configuration
Generator Installed N
Generator Type AC Size 5.0 kW
Generator Start Manual
AUX Output Device Port 1
Back Continue
Wizard Battery Charging
Absorb Voltage 57.6 VDC Time 1.0
Float Voltage 54.4 VDC Time 1.0
Equalize Voltage 60.0 VDC Time 3.0
Re-Float Voltage 44.0 VDC
Back Continue
Wizard AC Configuration
AC Output Voltage 230 VAC
AC Phase Single
AC Input Breaker Size 50 A
Maximum Output Load 30 A
Back Continue
Wizard System Type
System Type Backup
System Voltage 48 VDC
Array Wattage 1000
Battery Type FLA Capacity 500 Ah
Back Continue
Wizard Battery Monitor
Shunt A
Connection Inverter
Back Continue
Wizard AC Configuration
AC Output Voltage 230 VAC
AC Phase Single
AC Input Breaker Size 50 A
Maximum Output Load 30 A
Back Continue
Wizard Battery Charging
Absorb Voltage 57.6 VDC Time 1.0
Float Voltage 54.4 VDC Time 1.0
Equalize Voltage 60.0 VDC Time 3.0
Re-Float Voltage 44.0 VDC
Back Continue
Wizard System Type
System Type Off Grid
System Voltage 48 VDC
Array Wattage 1000
Battery Type FLA Capacity 500 Ah
Back Continue
Main Menu
Settings >>
Configuration Wizard >>
Device Data Logs >>
Event Logs >>
Firmware Update >>
Configuration Wizard
New Configuration
Settings Menu
System >>
Inverter >>
Charge Controller >>
Battery Monitor >>
MATE3 >>
System
System Configuration
System Information >>
Save / Store Information >>
Firmware Version >>
Date and Time >>
LCD Display >>
Firmware Versions
MATE3 003.002.005
1: VFXR3048E 001.006.002
2: VFXR3048E 001.006.002
Main Menu
Settings >>
Configuration Wizard >>
Device Data Logs >>
Event Logs >>
Firmware Update >>
Settings
!
CAUTION: Equipment Damage
These procedures should be done by a qualified installer who is trained on programming inverter power systems. Failure to set
accurate parameters for the system could potentially cause equipment damage. Damage caused by inaccurate programming is
not covered by the limited warranty for the system.
IMPORTANT
Check the firmware revision of all OutBack devices before use. The MATE3 system display must be revision 003.002.xxx or
higher. If the revision is lower, the MATE3 and inverter may not communicate or operate correctly.
Wizard High Battery Transfer
Mode Disabled
Grid Connect 48.0 VDC Delay 60 Min
Grid Disconnect 52.0 VDC Delay 60 Min
Grid Connect SOC 60% Disconnect SOC 95%
Back Continue
Wizard Generator Configuration
Generator Installed Y
Generator Type AC Size 5.0 kW
Generator Start Manual
AUX Output Device Port 1
Back Continue
Wizard Battery Monitor
Shunt C
Connection Charge Controller
Back Continue