R O O M I E D U A L
3. Technical
data
The unit is rated for indoor application with the ambient
temperature ranging from -25°C up to +50°C and relative
humidity up to 97 %.
The unit is rated as a class II electric appliance.
Roomie Dual
Speed
I
II
III
Airflow heat recovery mode (m
3
/h)
10
20
30
Airflow ventilation mode (m
3
/h)
10
20
30
Airflow exhaust mode (m
3
/h)
20
40
60
Sound pressure Lp(A) 3m dB
20
32
39
Sound power Lw(A) dB
37
49
56
Power consumption (W)
2,9
4,6
6,8
Current (A)
0,031
0,048
0,096
Fan speed (o/min.)
1030
1760
2690
Sound absorption D
n,e,w
(C;Ctr)
35 (-1;-4)
Voltage (V/50-60Hz)
100-240V
Filter class
G3
Ingress protection
IP 24
Operating temperature*
-25°C to 50°C
Wall thickness
280-500 mm
1. Purpose
The ventilator is designed to ensure continuous mechani-
cal air exchange in flats, cottages, hotels, cafes and other
domestic and public premises.
The ventilator is equipped with a ceramic regenerator that
enables supply of fresh filtered air heated by means of
extract air heat energy regeneration.
The ventilator is designed for through-the-wall-mounting.
!
The choice of unit installation location
must prevent unauthorized access by
unattended children.
The unit is rated for continuous operation.
Transported air must not contain any flammable or explo-
sive mixtures, evaporation of chemicals, sticky substances,
fibrous materials, coarse dust, soot and oil particles or
environments favourable for the formation of hazardous
substances (toxic substances, dust, pathogenic germs).
!
Turn off the unit if the air temperature
is outside the temperature range
stated in the technical data.
2. Delivery
set
Name
Number
Indoor unit of the ventilator
1 item
Air duct
1 item
Air flow separator
3 items
Assembled cartridge
1 item
Outer ventilation hood
1 item
Remote control
1 item
Cardboard template
1 item
Fastening set
2 packs
User’s manual
1 item
Packing box
1 item
Ingress Protection (IP) rating from solid objects and liquids
IP 24.
The unit design is regularly improved, so some models may
slightly differ from those ones described in this manual.
*Minimum operating temperature is
measured at an indoor humidity of 35% RH.
Variations in temperature and humidity may
lead to freezing at higher temperatures
than specified.
In the event of possible freezing, take the
cartridge out with the regenerator and fan.
Let it thaw at room temperature.
Wait to start the unit if the temperature
and humidity conditions are unchanged.
Alternatively, chose ventilation mode which
reduces indoor humidity and the risk of
freezing. The air is then continuously venti-
lated in one direction.
For Roomie Dual; activating the built-in
humidity sensor will activate both fans in
exhaust mode at maximum speed until the
humidity level is reduced to below set point.