background image

Roomie Dual

116027EN-05
2020-03

Assembly and Operation Instructions

 

Heat recovery single-room reversible ventilation unit

ART. NR.:

115999

Содержание Roomie Dual

Страница 1: ...Roomie Dual 116027EN 05 2020 03 Assembly and Operation Instructions Heat recovery single room reversible ventilation unit ART NR 115999...

Страница 2: ...2 R O O M I E D U A L...

Страница 3: ...ivery set 6 3 Technical data 6 4 Product desciption 8 5 Mounting and set up 10 6 Connection to power mains and control 14 7 Technical maintenance 22 8 Troubleshooting 24 9 Storage and transportation r...

Страница 4: ...physical or mental capacity or by persons with lacking experience or knowledge provided they have received instructions in the safe use of the appliance or are supervised to ensure safe use and provid...

Страница 5: ...ut the installation and maintenance operations with wet hands Do not operate the unit outside the temperature range stated in the user s manual Do not operate the unit in aggressive or explosive envir...

Страница 6: ...s evaporation of chemicals sticky substances brous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic ge...

Страница 7: ...h Roomie Dual 280 500 Front panel Outer ventilation hood Air duct length 235 71 285 207 85 137 138 Roomie Dual Overall dimensions of the indoor unit mm Standard duct is 500 mm which can be cut to min...

Страница 8: ...objects to the ventilator Unit design Air ow separators Designed for separation of supply and exhaust air streams Outer ventilation hood Prevents ingress of water and foreign objects into the ventilat...

Страница 9: ...as three operation modes Regeneration One of the fans of the ventilator operates in extract mode and the other one in supply mode The fans change their rotation direction every 70 seconds Ventilation...

Страница 10: ...very The air duct end must protrude for the distance that enables installation of the outer ventilation hood 0 3 mm min 3 mm Insert the air duct into the wall as shown in the picture on the left Insta...

Страница 11: ...of the master plate with respect to the horizon line it is recommended to use a builder s level Then mark the fastening holes for installation of the sup plied dowels and drill the holes to a required...

Страница 12: ...e wall with the screws supplied with the mounting kit of the ventilator Insert the wires under the cable clamp and connect the socket connector to the circuit board The mark must be directed upwards R...

Страница 13: ...ators in the air duct until it bumps up the cartridge Mark the last air ow separator to be ush with the air duct face remove it from the air duct and cut the exces sive part of the last air ow separat...

Страница 14: ...from underneath the unit to the back Any connections in the terminal according to the wiring diagram Cable clamp Cable clamp The unit is rated for connection to single phase AC 100 240 V 50 60 Hz pow...

Страница 15: ...tible with the unit When this is activated the ventilator switches to high speed The ventilators can be connected in series and in parallel with a central control by the master ventilator In case of i...

Страница 16: ...L N L In Gnd Gnd Out NO1 NO2 12V Power input 100 240 V 50 60 Hz to the next ventilator Master Slave 1 Slave N Master Slave 1 Slave N N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2...

Страница 17: ...llowed The switch position enables deactivation of the unit with the button on the side control panel 1 Turning the unit off is forbidden The switch position disables deactivation of the unit with the...

Страница 18: ...Function 3 4 5 Humidity control is OFF 3 4 5 Humidity setpoint 40 3 4 5 Humidity setpoint 50 3 4 5 Humidity setpoint 60 3 4 5 Humidity setpoint 70 3 4 5 Humidity setpoint 80 Position Function 6 7 Tim...

Страница 19: ...ce is follows low medium high speed Off Turning unit ON OFF Speed selection Regeneration mode In this mode the fans rotation direction changes to opposite every 70 seconds This operation mode enables...

Страница 20: ...ir ow separator by pulling one of the side clamps Install the front part of the front panel and press it gently to close the air duct The fan turns off automatically The unit functionality is not chan...

Страница 21: ...e Alarm indicator of the Master unit indicates an alarm in the network of the connected ventilation units Its blinking indicates shutdown of a speci c ventilation unit in the network In case of an eme...

Страница 22: ...s Uplift it with a at screw driver of a respective size Disconnect the socket from the circuit board Do not pull the wires Use a at screwdriver to disconnect the socket UP Never remove the control boa...

Страница 23: ...ct the Seller Some dust may accumulate on the heat exchanger block even in case of regular maintenance of the lters Clean the regenerator regularly to ensure its high heat recovery ef ciency Vacuum cl...

Страница 24: ...n the screws of the ventilator or the outer ventilation hood 9 Storage and transportation regulations Store the unit in the manufacturer s original packing box in a dry closed ventilated premise with...

Страница 25: ...er States relating to electromagnetic compatibility Producer VENTILATION SYSTEMS PrJSC 1 Mikhaila Kotzubinskogo St Kiev 01030 Ukraine Type Single room ventilators Roomie One Wi Roomie Dual Roomie Dual...

Страница 26: ...26 R O O M I E D U A L...

Страница 27: ...27 R O O M I E D U A L...

Страница 28: ...Flexit AS Televeien 15 N 1870 rje www exit no...

Отзывы: