background image

Pro7

Bathroom fan and Heat mover

Operating and installation instructions

115461EN-01 

2016-02

Type: K7

Содержание Pro7

Страница 1: ...Pro7 Bathroom fan and Heat mover Operating and installation instructions 115461EN 01 2016 02 Type K7...

Страница 2: ...or mental capacity or who lack experience and knowledge providing they have received guidance or been instructed in the safe use of the device and understand the risks involved Children must not be al...

Страница 3: ...s six different selectable operating functions for performing air extraction in all homes with natural ventilation It has been designed and approved for installation in wet rooms IP44 such as WCs bath...

Страница 4: ...ll frame cover is retained by 3 screws Untighten these and remove the cover The screws will be retained by their gaskets and do not need to be fully unscrewed 2 Gaskets To avoid water penetrating the...

Страница 5: ...onnection can either be performed from the rear concealed or from the top external see also fig 2b Make a hole in the gasket with a pricker or similar sharp tool b Position the wall frame so that the...

Страница 6: ...al connection NB May only be carried out by qualified electrician During any electrical work on the fan the voltage supply must be disconnected The fan is designed for permanent installation at 230 VA...

Страница 7: ...ate downwards arrow upwards b Reassemble and lock the motor unit in the wall frame by turning it clockwise To locate the correct position for the bayonet mount the multi function selector must be in p...

Страница 8: ...or if the relative humidity RH exceeds 70 When the humidity level recedes the fan returns to basic airflow or stops Depending on the choice of function see next page the fan will operate at High speed...

Страница 9: ...ree speeds Basic flow low speed 40 m3 h Presence sensor medium speed 60 m3 h Humidity control high speed 95 m3 h Position 2 As for position 1 but humidity control is set to max speed 110 m3 h Position...

Страница 10: ...integral all pole switch Lift the motor unit out of the wall frame see fig 1 in the Installation section Clean the opening duct and motor unit with a damp cloth if necessary a mild detergent may be us...

Страница 11: ...ld waste It must be taken to a reception station for recycling of electric and electronic equipment By ensuring the correct disposal of the equipment you will contribute to preventing the negative con...

Страница 12: ...12 175 45 10 99 25 Dimensions...

Страница 13: ...on class Class II Airflow Minimum speed 40 m3 h Medium speed 60 m3 h High speed 95 m3 h Max speed 110 m3 h Max pressure 48 Pa Sound pressure 17 25 dB A 3m Weight 0 48 Kg Ambient temperature 5 35 C Duc...

Страница 14: ...Standard Certificate Test report EN 60335 1 2012 A11 Intertek Semko 1510297 Intertek Semko 1510297STO 001 EN 60335 2 80 2003 A1 A2 Intertek Semko 1510297 Intertek Semko 1510297STO 001 EN 62233 2008 I...

Страница 15: ...15...

Страница 16: ...Flexit AS Televeien 15 1870 rje Norway www flexit no...

Отзывы: