6
EQ 2
1. Technical
data
The unit is designed for indoor use. The units is
constantly being improved, so some models can slightly
GLHUIURPWKRVHRQHVGHVFULEHGLQWKLVPDQXDO
Eq 2 (2 units)
Speed
I
II
III
$LUȵRZP
3
/h)
15
30
50
Sound pressure* Lp(A) 3m dB
19
28
37
Sound power* Lw(A) dB
36
45
54
Power consumption* (W)
1,6
3
5,6
Current* (A)
0,018
0,032
0,06
Fan speed (rpm)
1030
1760
2690
Voltage (V/50-60Hz)
100-240V
Filter class
G3 (F8 accessories)
Ingress protection
IP 24
Operating temperature
**
–15 °C to +40 °C
Wall thickness
350-500 mm
* Per unit
2. Purpose
The unit is designed to ensure continuous mechanical
air exchange in houses, apartments, commercial
buildings and other utility and public spaces.
The unit is equipped with a ceramic regenerator that
HQDEOHVVXSSO\RIIUHVKȴOWHUHGDLUKHDWHGE\PHDQVRI
extract air heat energy regeneration.
The unit is designed for through-the-wall mounting.
!
The choice of unit installation
location must prevent unauthorized
access by unattended children.
The unit is rated for continuous operation.
7UDQVSRUWHGDLUPXVWQRWFRQWDLQDQ\ȵDPPDEOHRU
explosive mixtures, evaporation of chemicals, sticky
VXEVWDQFHVȴEURXVPDWHULDOVFRDUVHGXVWVRRWDQGRLO
particles or environments favourable for the formation
of hazardous substances (toxic substances, dust, patho-
genic germs).
!
7XUQRWKHXQLWLIWKHDLUWHPSH
ature is outside the temperature
range stated in the technical data.
3. Delivery
set
Name
Number
Air duct
2 item
Sound-absorbing layer
2 item
Assembled cartridge
2 item
Internal square ventilation grille
2 item
External grille, aluminium
2 item
External grille, plastic*
2 item
Control panel
1 item
Fastening set
1 pack
Mounting box
2 item
User's manual
1 item
Packing box
1 item
*available
**Variations in temperature and
humidity may lead to freezing at higher
WHPSHUDWXUHVWKDQVSHFLȴHG
In the event of possible freezing, take
the cartridge out with the
regenerator and fan. Let it thaw at room
temperature.
Wait to start the unit if the temperature
and humidity conditions are unchanged.
Alternatively, chose ventilation mode
which reduces indoor humidity and the
risk of freezing. The air is then
continuously ventilated in one direction.