To scribe the correct locations for the component seal setting length use the following procedure:

1

. Reassemble the pump, including the shaft sleeve, seal chamber cover, and impeller as shown in

Figure 8

.

After adjusting the impeller, apply layout dye to the shaft (or shaft sleeve) at the face of the seal chamber,
and scribe a line in the dye showing the location of the chamber face as shown in

Figure 9

.

2

. Measure the distance from the stationary mating ring face to the seal chamber face. This can be

accomplished by simply measuring the distance from the top of the gland gasket to the mating ring as
seen in

Figure 10

The future location of Line #2 is shown as a reference for the reader.

3

. Disassemble the pump and apply layout dye at the approximate location of the seal face. Measure the seal

face distance (L) from Line #1 and scribe Line #2 into the dye as shown in

Figure 11

.

4

. From the seal face location, measure back along the shaft to the specified operating length (C) and scribe

a third line (Line #3,

Figure 12

).

SEAL INSTALLATION

Complete the layout and marking of the shaft for
installation as described earlier before beginning
installation. A complete assembly should resemble

Figure 13

.

1

. Remove the seal from its packaging and

inspect for damage to any components and
seal faces.

Grease, scratches, or nicks on the seal
faces may cause leakage.

2

. Ensure the shaft and seal housing have been

properly cleaned as described in the
preparation section.

3

. Evenly press the mating ring into the gland. Be

careful to keep the face clean and use a
suitable and compatible cleaning solvent if the
face gets smudged or dirty.

4

. Gently position the gland with installed mating

ring on the shaft facing, but clear of, the seal
chamber.

Be careful to not damage the mating ring
while setting the gland into position.

5

. Separate the drive hub, packing, and bellows

assembly by removing the cap screws from the
drive hub.

6

. Slide the bellows assembly along the shaft until

it is just past Line #2.

7

. Lightly lubricate the shaft packing with a

suitable and compatible lubricant. Slide the
drive hub and packing on the shaft in the
proper orientation facing the end of the bellows
assembly (

Figure 14

).

8

. Position the back of the drive hub to line up

with the setting length scribe line (Line #3).

9

. Fix the drive hub in position by alternately

tightening the provided cup point set screws to
the recommended torque values in the table
below (

Figure 15

).

10

. Bring the packing and bellows assembly back

to the drive hub. Use the socket head cap
screws to draw in and compress the packing
until the specified 0.050 in. setting gap is
achieved (

Figure 16

).

11

. Ensure the seal faces are clean and dry using

a suitable and compatible cleaning solvent for
the face material and elastomers.

12

. Reassemble the pump according to OEM

specifications.

13

. Bring the gland with the mating ring installed

into position and make sure that it mounts
concentric to the shaft.

Page 5 of 9

Содержание STYLE 60

Страница 1: ...Lane Rua Javaés 441 443 1719 South Sonny Avenue 7545 E Orem Drive Williston VT 05495 Bom Retiro Sao Paulo Gonzales LA 70737 Houston TX 77075 Brazil CEP 01130 010 TEL 802 878 8307 TEL 55 11 3736 7373 TEL 225 484 0007 TEL 832 801 7424 FAX 802 878 2479 FAX 55 11 3736 7355 FAX 225 341 8922 REVISED February 2021 ...

Страница 2: ...ication 4 Inspect the replacement seal prior to removal of the old seal or installation of the new seal using the technical information provided in this document Contact a Flexaseal representative if there are any questions 5 Follow plant safety regulations and procedures throughout the disassembly installation process including but not limited to the following Lockout tagout procedures SDS consul...

Страница 3: ...ce and seat counterbore surfaces of rust burrs grit sharp edges and set screw damage using fine emery cloth Wipe clean Avoid making flat spots reducing shaft diameter or increasing seat bore diameter 4 If the pump is equipped with a shaft sleeve verify the condition of its O ring or gasket and ensure that it is properly located fully engaged against step hook snap ring 5 Sealing surfaces and the s...

Страница 4: ...al shaft movement shaft runout 0 0015 0 003 in Fig 3 Radial bearing fit 0 002 0 003 in Fig 4 Bearing frame perpendicularity 0 0005 in in Fig 5 Axial shaft movement end play 0 003 in Fig 6 Seal chamber bore concentricity 0 005 in Fig 7 Seal chamber face squareness 0 0005 in in For proper function and satisfactory operation of the seal it is imperative that connections dimensions finishes and alignm...

Страница 5: ... on any part of a step or groove prior to final installation Style 60 62 65 high temperature bellows rotaries are exclusively intended for inside mounted use Do not mount outside of the seal chamber 1 Do not scratch the shaft or sleeve when scribing during the layout procedure Figure 8 Fully assembled pump without seal 1 Figure 9 Layout dye application and scribe 2 1 GLAND GLAND GASKET L MATING RI...

Страница 6: ...e leakage 2 Ensure the shaft and seal housing have been properly cleaned as described in the preparation section 3 Evenly press the mating ring into the gland Be careful to keep the face clean and use a suitable and compatible cleaning solvent if the face gets smudged or dirty 4 Gently position the gland with installed mating ring on the shaft facing but clear of the seal chamber Be careful to not...

Страница 7: ...t recheck installation 4 Verify that all plumbing and piping plans for the seal are connected and configured according to best practice 5 Flood the pump vent all air from the seal chamber and check the seal for leakage 6 Ensure all plumbing and venting are free of obstruction and that the chamber is filled with liquid Check that all alarms connected to auxiliary systems are properly functioning to...

Страница 8: ...nt has been used with toxic or hazardous fluids ensure that it is decontaminated and neutralized before decommission begins There is often residual fluid remaining from the draining process so consult the pump OEM for special cases REMOVING THE SEAL Before opening the pump to remove the seal the warning stated above regarding toxins and hazardous products must be reiterated Make note of all fluids...

Страница 9: ...375 2 000 72 4 500 5 375 2 000 74 4 625 5 625 2 000 76 4 750 5 625 2 000 Style Bellows size Shaft OD Seal A B 16x 875 1 62 18 1 000 1 75 20X 1 125 1 87 22 1 250 2 00 24X 1 375 2 12 26 1 500 2 37 28 1 625 2 37 30 1 750 2 50 32 1 875 2 62 34 2 000 2 75 36 2 125 3 00 38 2 250 3 12 40 2 375 3 25 42 2 500 3 37 44 2 625 3 50 46 2 750 3 75 48 2 875 3 87 50 3 000 4 00 52 3 215 4 12 54 3 250 4 25 56 3 375 ...

Страница 10: ...ubject to misuse misapplication neglect alteration accident or physical damage c have been used in a manner contrary to FAS s instructions for installation operation and maintenance d have been damaged from ordinary wear and tear corrosion or chemical attack e have been damaged due to abnormal conditions vibration failure to properly prime or operation without flow f have been damaged due to a def...

Отзывы: