LD 15-10 125 R / LD 15-10 125
17
Noise and Vibration
The noise and vibration values have been
determined in accordance with EN 60745.
The A evaluated noise level of the power tool is
typically:
– Sound pressure level:
87.3 dB(A);
– Sound power level:
98.3 dB(A);
– Uncertainty: K = 3 dB.
Total vibration value (when sanding concrete
areas):
– Emission value:
a
h
= 6.4 m/s
2
– Uncertainty: K = 1.5 m/s
2
^ííÉåíáçå
qÜÉ=áåÇáÅ~íÉÇ=ãÉ~ëìêÉãÉåíë=êÉÑÉê=íç=åÉï=
éçïÉê=íççäëK=a~áäó=ìëÉ=Å~ìëÉë=íÜÉ=åçáëÉ=~åÇ=
îáÄê~íáçå=î~äìÉë=íç=ÅÜ~åÖÉK
klqb
The vibration emission level given in this
information sheet has been measured in
accordance with a standardised test given
in EN 60745 and may be used to compare
one tool with another. It may be used for
a preliminary assessment of exposure.
The declared vibration emission level represents
the main applications of the tool.
However if the tool is used for different
applications, with different accessories or poorly
maintained, the vibration emission may differ.
This may significantly increase the exposure
level over the total working period
For a precise estimation of the vibration load the
times should also be considered during which
the power tool is switched off or even running,
but not actually in use. This may significantly
increase the exposure level over the total
working period
Identify additional safety measures to protect
the operator from the effects of vibration such
as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
`^rqflk>
tÉ~ê=É~ê=éêçíÉÅíáçå=~í=~=ëçìåÇ=éêÉëëìêÉ=
~ÄçîÉ=UR=Ç_E^FK
Technical specifications
Machine type
Renovation sander
LD 15-10 125 R
LD 15-10 125
Mains voltage
V/Hz
230/50
Protection class
II /
Power input
W
1450
Speed
r.p.m.
10,000
Tool holder
M14
Max. disc diameter
mm
125
Weight (without power cord)
kg
2.9
3.2